Canary CN-1056 User Manual

Page of 40
38
Optical Insertion Loss estimation:
• Example 3 of Origin to Remote (Point-to-Point) (link) Loss
Calculation with two intermediate, OADM (client Drop, Add and
Pass-Thru) stages – assumes one λ per OADM Drop-point.
• Calculates accumulated typical and maximum path Losses from
Origin through two OADM stages to Remote end-point.
Table (C-3)
Insertion Loss: Each
Insertion
Insertion
Insertion
Acc. Loss
Insertion
Insertion
Insertion
Acc. Loss at
Total Loss at end-
Mux + De-Mux stage
Loss (1st)
Loss (1st)
Loss (1st)
at (1st)
Loss (2nd)
Loss (2nd)
Loss (2nd)
(2nd) Drop
point Demux w/ two
(typically at segment
 Drop point
Add point
Pass-Thru
Drop point
Drop point
Add point
Pass-Thru
point
Pass-Thru stages
end-points)
(M
O
 & D
O
)  (M
R
 & D
R
)
(C)
(B)
(E)
(M
O
 + C)
(F)
(G)
(H)
(M
O
 + E + F)
(M
O
 + E + H + D
R
)
1.2 dB            1.2 dB
1.0 dB
1.0 dB
0.5 dB
2.2 dB
1.0 dB
1.0 dB
0.5 dB
2.7 dB
3.4 dB
(Typical Optical Loss)
2.4 dB            2.4 dB
1.4 dB
1.4 dB
1.0 dB
3.8 dB
1.4 dB
1.4 dB
1.0 dB
4.8 dB
6.8 dB
(Maximum Optical Loss)
• Given: Origin Multiplexer/De-Multiplexer (CM-4MD6-A) losses
(M
O
 & D
O
) and Remote site Mux/De-Mux (CM-4MD6-A)
losses (M
R
 & D
R
) plus two OADM points & losses (C, B, E) and
(F, G, H) in the optical path.
Coarse Wavelength Division Multiplexing
Optical Insertion Losses