FO Universal Cables
13.1
Stranded 
Loose Tube
OS2
Stranded 
Loose Tube
OM2
Stranded 
Loose Tube
OM3
Stranded 
Loose Tube
OM4
Stranded 
Loose Tube
OM1
Standards
Standard
 ITU G.652 D 
(low water peak)
 IEC60793-
2-10
 IEC60793-
2-10
 IEC60793-
2-10
 IEC60793-
2-10
Mechanical Characteristics
Calbe structure acc. DIN/VDE 0888
A/I-DQ(ZN)
BH 1..48x12
A/I-DQ(ZN)
BH 1..48x12
A/I-DQ(ZN)
BH 1..48x12
A/I-DQ(ZN)
BH 1..48x12
A/I-DQ(ZN)
BH 1..48x12
Cable diameter in mm (4-24 fibers)
≤ 12,5
≤ 12,5
≤ 12,5
≤ 12,5
≤ 12,5
Max. pulling tension short-term/long-term in N
6000
6000
6000
6000
6000
Max. Crush resistance in N/m
30000
30000
30000
30000
30000
Min. bending radius short-term/long-term
250 / 190
250 / 190
250 / 190
250 / 190
250 / 190
Colour of outer jacket
yellow
yellow
yellow
yellow
yellow
Weight in kg/km
185
185
185
185
185
Climatic Characteristics
Operating temperature
-25 / +60
-25 / +60
-25 / +60
-25 / +60
-25 / +60
Storage temperature
-25 / +70
-25 / +70
-25 / +70
-25 / +70
-25 / +70
Installation temperature in °C
 -5 / +50
 -5 / +50
 -5 / +50
 -5 / +50
 -5 / +50
Flame retardancy
 IEC 60332-1-2
 IEC 60332-1-2
 IEC 60332-1-2
 IEC 60332-1-2
 IEC 60332-1-2
Halogen-free
 IEC 60754-2
 IEC 60754-2
 IEC 60754-2
 IEC 60754-2
 IEC 60754-2
Watertightness
 IEC 60794-
1-2-F5B
 IEC 60794-
1-2-F5B
 IEC 60794-
1-2-F5B
 IEC 60794-
1-2-F5B
 IEC 60794-
1-2-F5B
Optical Characteristics
Fiber Class acc. to ISO/IEC 11801
OS2
OM2
OM3
OM4
OM1
Max. attenuation in dB/km at 850/1300 nm
-
2,8 / 0,90
3,0 / 1,0
3,0 / 1,0
3,2 / 1,1
Max. attenuation in dB/km at 1310/1550 nm
0,40 / 0,30
-
-
-
-
Bandwidth in MHz x km at 850/1300 nm
-
600 / 1200
1500 / 500
3500 / 500
200 / 600
Dispersion in ps/nm x km
≤ 3,5 / ≤ 18
-
-
-
-
Link Class OF in m at 1310/1550 nm: 1 Gbit/10 Gbit
10000 / 10000
-
-
-
-
Link Class OF in m at 850 nm: 1 Gbit/10 Gbit
-
600 /82
900 / 300
900 / 550
275 / 33
Link Class OF in m at 1300 nm: 1 Gbit/10 Gbit
-
600 /n.a.
550 / n.a.
550 / n.a.
550 / n.a.
Technical Characteristics
Application
outdoor, not for direct burial/indoor
 
–
Order no.
Fiber type
Number of 
Fibers
Cable diameter
Pulling tension short-
term/long-term in N
Cable Colour
Weight
L08020A0112
E9/125 OS2
12
≤ 6,1 mm
≥1500 / ≥700
orange
37
L08020A0124
E9/125 OS2
24
≤ 6,1 mm
≥1500 / ≥700
orange
37
L08020B9001
E9/125 OS2
48
≤ 12,5 mm
≥6000 / ≥3000
yellow
185
 
–
Order no.
Fiber type
Number of 
Fibers
Cable diameter
Pulling tension short-
term/long-term in N
Cable Colour
Weight
L08021A0104
G50/125 OM2
4
≤ 6,1 mm
≥1500 / ≥700
orange
37
L08021A0106
G50/125 OM2
6
≤ 6,1 mm
≥1500 / ≥700
orange
37
L08021A0108
G50/125 OM2
8
≤ 6,1 mm
≥1500 / ≥700
orange
37
L08021A0112
G50/125 OM2
12
≤ 6,1 mm
≥1500 / ≥700
orange
37
L08021A0324
G50/125 OM2
24
≤ 6,1 mm
≥1500 / ≥700
orange
37