Intel 200 MHz FV8050366200 User Manual

Product codes
FV8050366200
Page of 51
PENTIUM® PROCESSOR WITH MMX™ TECHNOLOGY
E
36
5/23/97 10:47 AM    24318502.DOC
INTEL CONFIDENTIAL
(until publication date)
Table 15.  Pentium
®
 Processor with MMX™ Technology AC Specifications for
66-MHz Bus Operation (Cont’d)
(See Table 10 for V
CC
 and T
CASE
 specifications, C
L
 = 0 pF.)
Symbol
Parameter
Min
Max
Unit
Figure
Notes
t
24b
PEN# Setup Time
4.8
ns
7
t
25a
BUSCHK#, EWBE#, PEN# Hold
Time
1.0
ns
7
t
25b
HOLD Hold Time
1.5
ns
7
t
26
A20M#, INTR, STPCLK# Setup
Time
5.0
ns
7
(12, 16)
t
27
A20M#, INTR, STPCLK# Hold
Time
1.0
ns
7
(13)
t
28
INIT, FLUSH#, NMI, SMI#,
IGNNE# Setup Time
5.0
ns
7
(12, 16, 17)
t
29
INIT, FLUSH#, NMI, SMI#,
IGNNE# Hold Time
1.0
ns
7
(13)
t
30
INIT, FLUSH#, NMI, SMI#,
IGNNE# Pulse Width, Async
2.0
CLK
(15, 17)
t
31
R/S# Setup Time
5.0
ns
7
(12, 16, 17)
t
32
R/S# Hold Time
1.0
ns
7
(13)
t
33
R/S# Pulse Width, Async.
2.0
CLK
15, 17)
t
34
D0-D63, DP0-7 Read Data
Setup Time
2.8
ns
7
t
35
D0-D63, DP0-7 Read Data Hold
Time
1.5
ns
7
t
36
RESET Setup Time
5.0
ns
8
(12, 16)
t
37
RESET Hold Time
1.0
ns
8
(13)
t
38
RESET Pulse Width, V
CC
 & CLK
Stable
15.0
CLK
8
(17)
t
39
RESET Active After V
CC
 & CLK
Stable
1.0
ms
8
Power up
t
40
Reset Configuration Signals
(INIT, FLUSH#) Setup Time
5.0
ns
8
(12, 16, 17)
t
41
Reset Configuration Signals
(INIT, FLUSH#) Hold Time
1.0
ns
8
(13)
t
42a
Reset Configuration Signals
(INIT, FLUSH#) Setup Time,
Async.
2.0
CLK
To RESET falling edge
(16)
t
42b
 Reset Configuration Signals
2.0
CLK
To RESET falling edge