Intel S2600JFQ BBS2600JFQ User Manual

Product codes
BBS2600JFQ
Page of 194
Connector/Header Locations and Pin-out 
Intel®
 
Server Board S2600JF TPS 
 
 
Revision 1.3 
Intel order number G31608-004 
122 
State 
ACPI 
Power LED 
S1 Sleep 
Yes 
~1 Hz blink 
S0 
Yes 
Solid on 
 
7.3.5 
System Status LED 
Note: The system status LED state shows the state for the current, most severe fault. For 
example, if there was a critical fault due to one source and a non-critical fault due to another 
source, the system status LED state would be solid on (the critical fault state). 
The system status LED is a bicolor LED. Green (status) shows a normal operation state or a 
degraded operation. Amber (fault) shows the system hardware state and overrides the 
green status. 
The Integrated BMC-detected state and the state from the other controllers, such as the 
SCSI/SATA hot-swap controller state, are included in the LED state. For fault states monitored 
by the Integrated BMC sensors, the contribution to the LED state follows the associated sensor 
state, with the priority going to the most critical state currently asserted. 
When the server is powered down (transitions to the DC-off state or S5), the Integrated BMC is 
still on standby power and retains the sensor and front panel status LED state established prior 
to the power-down event. 
The following table maps the system state to the LED state: 
 
 
Figure 46. System Status LED (A) and ID LED (B) 
 
Table 64. System Status LED 
Color 
State 
System Status 
Description