Intel S2600JFQ BBS2600JFQ User Manual

Product codes
BBS2600JFQ
Page of 194
Intel®
 
Server Board S2600JF TPS  
Connector/Header Locations and Pin-out 
Revision 1.3 
 
 
Intel order number G31608-004 
123 
Color 
State 
System Status 
Description 
Green 
Solid on 
Ok 
System ready 
Green 
~1 Hz blink 
Degraded 
BIOS detected 
 
Unable to use all of the installed memory (more than one 
DIMM installed).
1
 
 
In a mirrored configuration, when memory mirroring takes 
place and system loses memory redundancy. This is not 
covered by (2).
1
 
 
PCI Express* correctable link errors. 
Integrated BMC detected 
 
Redundancy loss such as a power supply or fan. Applies 
only if the associated platform subsystem has redundancy 
capabilities. 
 
CPU disabled 
– if there are two CPUs and one CPU is 
disabled. 
 
Fan alarm 
– Fan failure. Number of operational fans should 
be more than minimum number needed to cool the system. 
 
Non-critical threshold crossed 
– Temperature, voltage, 
power nozzle, power gauge, and PROCHOT2 (Therm Ctrl) 
sensors. 
 
Battery failure.  
 
Predictive failure when the system has redundant power 
supplies.
 
Amber 
~1 Hz blink 
Non-Fatal 
Non-fatal alarm 
– system is likely to fail: 
BIOS Detected 
 
In non-mirroring mode, if the threshold of ten correctable 
errors is crossed within the window.
1
 
 
PCI Express* uncorrectable link errors. 
Integrated BMC Detected 
 
Critical threshold crossed 
– Voltage, temperature, power 
nozzle, power gauge, and PROCHOT (therm Ctrl) sensors. 
 
VRD Hot asserted. 
 
Minimum number of fans to cool the system is not present 
or has failed.
 
Amber 
Solid on 
Fatal 
Fatal alarm 
– system has failed or shut down: 
BIOS Detected 
 
DIMM failure when there is one DIMM present and no good 
memory is present.
1
 
 
Run-time memory uncorrectable error in non-redundant 
mode.
1
 
 
CPU configuration error (for instance, processor stepping 
mismatch). 
Integrated BMC Detected 
 
CPU CATERR signal asserted. 
 
CPU 1 is missing. 
 
CPU THERMTRIP. 
 
No power good 
– power fault. 
 
Power Unit Redundancy sensor 
– Insufficient resources 
offset (indicates not enough power supplies are present).
 
Off 
NA 
Not ready 
Main power off
 
Notes: 
1.  The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to 
provide the contribution to the system status LED.
 
 
2.  Support for an upper, non-critical threshold limit is not provided in default SDR configuration. However if a 
user does enable this threshold in the SDR, then the system status LED should behave as described.