Intel S2600JFQ BBS2600JFQ User Manual
Product codes
BBS2600JFQ
Intel®
Server Board S2600JF TPS
Platform Management Functional Overview
Revision 1.3
Intel order number G31608-004
33
Throughout this document, the PCI Express* interface may also be referred to as the
“uplink” interface
“uplink” interface
Network Interface: Single network port connecting the device to a network fabric in
one of the configurations described in the following table:
Table 12. Network port configuration
Port Configured as
10/20/40/56 Gb/s InfiniBand*
Flash interface: Chip initialization and host boot
I2C Compatible Interfaces: For chip, QSFP connector, and chassis configure
and monitor
Management Link: Connect to BMC through SMBus* and NC-SI
Others including: MDIO, GPIO and JTAG
3.5.2
Quad Small Form-factor Pluggable (QSFP) connector
Port of the Mellanox* ConnectX-3* is connected to a single QSFP connector on Intel
®
Server
Board S2600JF (available on SKU: S2600JFQ and S2600JFF). Following is the application
reference between Mellanox* ConnectX-3* and QSFP:
reference between Mellanox* ConnectX-3* and QSFP:
Figure 17. Connection between ConnectX
®
-3 and QSFP
The QSFP module and all pins shall withstand 500V electrostatic discharge based on the
Human Body Model per JEDEC JESD22-A114-B.
Human Body Model per JEDEC JESD22-A114-B.
The module shall meet ESD requirements given in EN61000-4-2, criterion B test specification
such that when installed in a properly grounded cage and chassis the units are subjected to
12KV air discharges during operation and 8KV direct contact discharges to the case.
such that when installed in a properly grounded cage and chassis the units are subjected to
12KV air discharges during operation and 8KV direct contact discharges to the case.
Note: InfiniBand* cables of 2 meters or 3 meters length are recommended to get better EMI
performance.
performance.