Intel S2600JFQ BBS2600JFQ User Manual

Product codes
BBS2600JFQ
Page of 194
Intel®
 
Server Board S2600JF TPS 
Platform Management Functional Overview 
Revision 1.3 
 
Intel order number G31608-004 
33 
Throughout this document, the PCI Express* interface may also be referred to as the 
“uplink” interface 
  Network Interface: Single network port connecting the device to a network fabric in 
one of the configurations described in the following table:  
Table 12. Network port configuration 
Port Configured as 
10/20/40/56 Gb/s InfiniBand* 
  Flash interface: Chip initialization and host boot 
  I2C Compatible Interfaces: For chip, QSFP connector, and chassis configure 
and monitor 
  Management Link: Connect to BMC through SMBus* and NC-SI 
  Others including: MDIO, GPIO and JTAG 
 
3.5.2 
Quad Small Form-factor Pluggable (QSFP) connector 
Port of the Mellanox* ConnectX-3* is connected to a single QSFP connector on Intel
®
 Server 
Board S2600JF (available on SKU: S2600JFQ and S2600JFF). Following is the application 
reference between Mellanox* ConnectX-3* and QSFP: 
 
Figure 17. Connection between ConnectX
®
-3 and QSFP 
The QSFP module and all pins shall withstand 500V electrostatic discharge based on the 
Human Body Model per JEDEC JESD22-A114-B
The module shall meet ESD requirements given in EN61000-4-2, criterion B test specification 
such that when installed in a properly grounded cage and chassis the units are subjected to 
12KV air discharges during operation and 8KV direct contact discharges to the case. 
Note: InfiniBand* cables of 2 meters or 3 meters length are recommended to get better EMI 
performance.