PROCESSOR FEATURES 
 
 
52 
5.2.6.3 Status 
Register 
 
The status register shown in Table 42 indicates which (if any) thermal value thresholds have been exceeded. 
It also indicates if a conversion is in progress or if an open circuit has been detected in the processor core 
thermal diode connection. Once set, alarm bits stay set until a status register read clears them. A successful 
read to the status register will clear any alarm bits that may have been set, unless the alarm condition 
persists
Table 42.  Thermal Sensor Status Register 
Bit Name 
Function 
7 (MSB) 
BUSY 
A one indicates that the device’s analog to digital converter is busy converting. 
RESERVED 
Reserved for future use
 
RESERVED 
Reserved for future use
 
RHIGH 
A one indicates that the processor core thermal diode high temperature alarm has 
activated. 
RLOW 
A one indicates that the processor core thermal diode low temperature alarm has 
activated. 
OPEN 
A one indicates an open fault in the connection to the processor core diode. 
RESERVED 
Reserved for future use. 
0 (LSB) 
RESERVED 
Reserved for future use. 
5.2.6.4 Configuration 
Register 
 
The configuration register controls the operating mode (standby vs. auto-convert) of the thermal sensor. 
Table 43 shows the format of the configuration register. If the RUN/STOP bit is set (high) then the thermal 
sensor immediately stops converting and enters standby mode. The thermal sensor will still perform analog to 
digital conversions in standby mode when it receives a one-shot command. If the RUN/STOP bit is clear (low) 
then the thermal sensor enters auto-conversion mode. 
Table 43.  Thermal Sensor Configuration Register 
Bit Name 
Reset 
State 
Function 
7 (MSB) 
RESERVED 
Reserved for future use. 
RUN/STOP 
Standby mode control bit. If high, the device immediately stops 
converting, and enters standby mode. If low, the device converts in 
either one-shot mode or automatically updates on a timed basis.. 
5-0 
RESERVED 
Reserved for future use. 
5.2.6.5 Conversion 
Rate 
Register 
 
The contents of the conversion rate register determine the nominal rate at which analog to digital conversions 
happen when the thermal sensor is in auto-convert mode. Table 44 shows the mapping between conversion 
rate register values and the conversion rate. As indicated in Table 44, the conversion rate register is set to its 
default state of 02h (0.25 Hz nominally) when the thermal sensor is powered up.
 
There is a ±25% error 
tolerance between the conversion rate indicated in the conversion rate register and the actual conversion rate. 
Table 44.  Thermal Sensor Conversion Rate Register 
Register Contents 
Conversion Rate (Hz) 
00h 0.0625 
01h 0.125 
02h 0.25