IBM Intel Xeon E5-2637 49Y8125 User Manual

Product codes
49Y8125
Page of 258
Intel® Xeon® Processor E5-1600/E5-2600/E5-4600 Product Families
137
Datasheet Volume One
Thermal Management Specifications
5.1.5
Thermal Metrology
The minimum and maximum case temperatures (T
CASE
 through 
 are measured at the geometric top center of the processor integrated heat 
spreader (IHS). 
 illustrates the location where T
CASE
 temperature 
measurements should be made. For detailed guidelines on temperature measurement 
methodology, refer to the Intel® Xeon® Processor E5-1600/E5-2600/E5-4600 Product 
Families Thermal/Mechanical Design Guide
.
Notes:
1.
Figure is not to scale and is for reference only.
2.
B1: Max = 52.57 mm, Min = 52.43 mm.
3.
B2: Max = 45.07 mm, Min = 44.93 mm.
4.
C1: Max = 43.1 mm, Min = 42.9 mm.
5.
C2: Max = 42.6 mm, Min = 42.4 mm.
6.
C3: Max = 2.35 mm, Min = 2.15 mm.
25
61.0
76.0
64
79
30
62.7
77.7
66
81
35
64.5
79.5
69
84
40
66.3
81.3
71
86
45
68.1
83.1
74
89
50
69.9
84.9
76
91
55
71.7
86.7
78
93
60
73.5
88.5
81
96
65
75.3
90.3
83
98
70
77.1
92.1
86
101
Table 5-30. 8-Core LV70W Thermal Profile Table, Embedded Server SKU (Sheet 2 of 2)
Maximum T
CASE
 (ºC)
Maximum DTS (ºC)
Power (W)
Long Term
Short Term
Long Term
Short Term
Figure 5-32. Case Temperature (T
CASE