Toshiba Strata CTX100 User Manual

Page of 100
Strata CTX670 Overview
CTX670 License Control
Strata CTX General Description    11/02
7
Network Interface
The processor has an on-board Ethernet 10Base-T Ethernet circuit for connection to Open 
Architecture Computer Telephony Interface (CTI) applications. This provides extensive call 
control and telephone support for CTI applications. The Ethernet Network Interface Card (NIC) 
port also enables connection to the following:
CTX Attendant Console
ACD server 
Local and Remote CTX WinAdmin PC
Soft Key Control of Voice Mail features
Maintenance Modem
A built-in maintenance modem (33.6Kbps/V.34) on the processor can provide point-to-point local 
or remote connection to the CTX WinAdmin administration software.
CTX670 Processor PCB Subassemblies
Subassemblies can be added to the processor PCBs to enable system expansion and provide 
additional features. The subassemblies are:
BEXS and BBMS expansion PCBs mount onto the processor PCBs to provide increased port 
capacity, from Basic (192 ports) to Expanded (672 ports). The BEXS provides switching 
capacity, and the BBMS provides memory capacity. For Basic and Expanded capacities of 
stations, lines and features, see 
Tables 3
~
7
. To expand the system, both subassemblies must be 
installed.
BSIS interface PCB which attaches to the BECU to provide up to four RS-232 interface ports 
for SMDR Call Accounting and SMDI or Toshiba Proprietary Voice Mail interface.
See 
Table 3 on page 11
 for the number of cabinets and universal PCB slots for the Basic and 
Expanded systems.
CTX670 License Control
The system size and feature capability is controlled using a software License Key Code. This key 
code is obtained from the Toshiba Internet FYI site during the ordering process and is installed 
onto the system processor via Strata CTX WinAdmin. Processor license codes activate system 
hardware capacities in the following increments.
The first 64 line/station ports do not require a license. Each additional set of four line/station 
ports requires one LIC670-4 PORTS license (maximum of 672 ports).
The on-board DTMF receiver circuit provides up to 32 DTMF receiver hardware circuits. The 
first four DTMF circuits do not require a license. Each additional set of four DTMF receiver 
circuits requires one LIC670-4 DTMF license (max. total of 32 DTMF circuits).
Note
DTMF tone receiver circuits are required for standard telephones, Voice Mail DTMF 
integration, Tie, DID and DNIS line service.
The optional RS-232 serial port interface (BSIS) provides two circuits to interface with Voice 
Mail, SMDI or Toshiba Proprietary Voice Mail integration, Call Accounting SMDR, and two 
for future applications. The first circuit does not require a license, but circuits two through four 
each require one LIC670-SER PORT license.
Get user manuals: 