Connecting Bare
DC Power Wires
To attach bare lead wires to the positive and negative terminals on the 
power supply, perform the following procedure:
1. Prepare adequate lengths of two solid or stranded 8 AWG DC power 
Figure 129. Stripping Solid or Stranded DC Power Wires
2. Use a #1 Phillips-head screwdriver to loosen the two screws on the 
plastic cover over the positive and negative terminals on the power 
supply and slide the cover to the right, as shown in Figure 116 on page 
161
. You may need to lift the locking handle slightly to access the 
bottom screw.
3. Use a #3 Phillips-head screwdriver to remove the two screws from the 
positive and negative terminals, as shown in Figure 117 on page 162.
4. Wrap the positive lead wire clockwise around one of the terminal 
screws and secure the screw and wire to the positive terminal 
connection on the terminal block with a #3 Phillips-head screwdriver. 
The positive terminal is on the left.
You may attach the wire to the terminal so that it extends either above 
or below the terminal block. Figure 130 on page 174 shows the wire 
above the terminal block. Allied Telesis recommends tightening the 
screw to 30 to 40 inch-lbs.