CAMERA PROGRAMMING
Extended Coaxitron protocol receivers can be operated without any programming changes, other than changing the camera title, if necessary. 
For other receiver control protocols, you must select the control type for the device connected to each video input.
If necessary, first program logical camera number.
PROGRAM LOGICAL NUMBERS
Default logical numbers start at 0001 and continue sequentially to 0048 (or to 0096 in a 96 x 16 system). To use a different numbering scheme, 
program new numbers on the Logical Camera Number screen.
Figure 39.  Program Logical Camera Numbers
The numbers in the PHY columns are the physical input numbers; each represents an actual BNC input on the rear panel of the CM6800 and 
cannot be changed.
In the LOG field for each physical camera input, assign a valid logical number (0001-9998). A valid number is any number from 0001 to 9998 that 
has not already been assigned to a physical camera input.
NOTE:  If you change a logical number, you cannot control the camera until you select the new logical number from the keyboard.
PELCO SWITCHER
MODEL CM6800E
MAIN MENU
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
CAMERA
LOGICAL CAMERA
MONITOR
ACCESS
TIME & DATE
PORT
PRIORITY
SEQUENCE
MACRO
ALARM CONTACTS
EVENT TIMER
SET AUXILIARY
SET PASSWORD
SYSTEM
ABOUT CM6800E
ENGLISH
RETURN
 
LOGICAL CAMERA NUMBER MENU
 
PHY LOG  PHY  LOG  PHY  LOG
 
01 0001 
17  0402 33  0033
 
02 0002 
18  0403 34  0034
 
03 0003 
19  0404 35  0035
 
04 0004 
20  0405 36  0036
 
05 0005 
21  0500 37  0037
 
06 0006 
22  0501 38  0038
 
07 0007 
23  0502 39  0039
 
08 0008 
24  0503 40  0040
 
09 0009 
25  0504 41  0041
 
10 0201 
26  0505 42  0042
 
11 
0202 27  0601  43  0043
 
12 0203 
28  0602 44  0044
 
13 0301 
29  0603 45  0045
 
14 0302 
30  0604 46  0046
 
15 0303 
31  0605 47  0047
 
16 0401 
32  0032 48  0048
 
 
RETURN