Panasonic PT-DZ680ULS User Manual

Page of 130
74 - ENGLISH
Chapter 4  Settings — [PROJECTOR SETUP] menu
[COOLING CONDITION]
Change the fan control depending on the direction of projection.
Set [COOLING CONDITION] correctly in accordance with the direction of projection referring to the following figure. It may shorten the life of 
the lamp if used in incorrect setting.
ƒ
ƒ
ƒ
ƒ
>83:$5'
6(77,1*@
>)/2256(77,1*@
>&(,/,1*6(77,1*@
>'2:1:$5
'6(77,1*@
3URMHFWLRQGLUHFWLRQ
1) 
Press as to select [COOLING CONDITION].
2) 
Press the <ENTER> button.
r
f
The 
[COOLING CONDITION] screen is displayed.
3) 
Press as to select a cooling condition.
4) 
Press the <ENTER> button.
5) 
When the confirmation is displayed, select [OK] 
or [CANCEL], and press the <ENTER> button.
[HIGH ALTITUDE MODE]
Set to [ON] to use the projector at 1 400 m (4 593 ft) to 2 700 m (8 858 ft) elevations.
1) 
Press as to select [HIGH ALTITUDE MODE].
2) 
Press qw to switch [HIGH ALTITUDE MODE].
r
f
The setting will change between [OFF] and [ON].
3) 
When the confirmation is displayed, select [OK] 
or [CANCEL], and press the <ENTER> button.
r
r
[HIGH ALTITUDE MODE]
[OFF]
When using at a place lower than 1 400 m (4 593 ft) above sea level
[ON]
When using at a high altitude (1 400 m (4 593 ft) or higher and lower than 2 700 m (8 858 ft) above sea 
level)
Note
r
f
The speed of the fan increases and the operation sound becomes louder when set to [ON].
[LAMP SELECT]
Switch between brightness of two lamps and that of single lamp from the two luminous lamps built into the projector body according to the 
use condition or purpose. When [SINGLE] is set, the lamp to be turned on is automatically selected based on the cumulative operating time of 
lamps.
1) 
Press as to select [LAMP SELECT].
2) 
Press qw to switch [LAMP SELECT].
r
f
The setting will change among [DUAL], [SINGLE], [LAMP1] and 
[LAMP2] each time you press the button.
3) 
Press the <ENTER> button.
r
r
[LAMP SELECT]
[DUAL]
Two lamps will light.
[SINGLE]
Single lamp will light. (The lamp with shorter cumulative operating time is selected automatically.)
[LAMP1]
Lamp 1 will light.
[LAMP2]
Lamp 2 will light.
Note
r
f
When [SINGLE], [LAMP1], or [LAMP2] is selected, if the lamp does not light or the cumulative operating time exceeds 2 500 hours (when 
[LAMP POWER] is set to [NORMAL]), the other lamp will light. When [DUAL] is selected, if either lamp does not light or the cumulative