    power good signal has been asserted. 
 
3.6.7    Reset after Shutdown 
        The power supply latches into a shutdown state because of a fault condition   
        on its outputs, the power supply returns to normal operating after the fault   
        has been removed and the PS_ON# (or AC input) has been cycled OFF/ON   
        with a minimum OFF time of 1 second. 
 
3.7 Output 
Protection 
Each DC output is protected from over voltage, over current and short circuit. The 
following sections include the details for these protection mechanisms. 
 
3.7.1    Over Current Protection 
    The power supply 
DC
 outputs are protected from supplying output current   
        above the maximum ratings defined in Table 1, and when output power is   
        less than 240VA
.
 With the exception of the 
5VSB
 output, all 
DC outputs
 
        are
 
latched
 
off in
 
the
 
event of
 
an
 
over-current event
 
on
 
any
 
of
 
the
 
DC
 
outputs.
 
        In
 
the
 
event
 
of
 
a short
 
circuit
 
on
 
any
 
output
except
 
the
 5VSB 
rail
all
 
outputs  
        are
 
disabled and
 
remain
 
disabled
 
until
 
the
 
power
 
supply is powered
 
off  back  
        on. The 5VSB rail will recover upon removal of the over current condition. 
3.7.2  Over Voltage Protection 
        The over voltage sense circuitry and reference reside in packages that are   
    separate and distinct from the regulator control circuitry and reference. No   
        single point fault is able to cause a sustained over voltage condition on any   
    or all outputs. The power supply provides latch-mode over voltage   
    protection defined as: 
        +5V output is between 5.7V to 6.5V 
    +12V output is between 13.3V to 15.5V 
        +3.3V output is between 3.7V to 4.5V 
3.7.3  Short Circuit Protection 
        The power supply DC outputs are protected from damage due to faults,   
        when any output shorts to ground. In the event of a short circuit on any   
        output, all outputs shall be disabled and remain disable until the power   
        supply is powered off and back on. The 5VSB rail will recover upon   
    removal of the over current condition.