iStarUSA TC-1U30FX2 Manual Do Utilizador
Page
9
power good signal has been asserted.
3.6.7 Reset after Shutdown
The power supply latches into a shutdown state because of a fault condition
on its outputs, the power supply returns to normal operating after the fault
has been removed and the PS_ON# (or AC input) has been cycled OFF/ON
with a minimum OFF time of 1 second.
3.7 Output
Protection
Each DC output is protected from over voltage, over current and short circuit. The
following sections include the details for these protection mechanisms.
3.7.1 Over Current Protection
The power supply
DC
outputs are protected from supplying output current
above the maximum ratings defined in Table 1, and when output power is
less than 240VA
.
With the exception of the
5VSB
output, all
DC outputs
are
latched
off in
the
event of
an
over-current event
on
any
of
the
DC
outputs.
In
the
event
of
a short
circuit
on
any
output
,
except
the
5VSB
rail
,
all
outputs
are
disabled and
remain
disabled
until
the
power
supply is powered
off back
on. The 5VSB rail will recover upon removal of the over current condition.
3.7.2 Over Voltage Protection
The over voltage sense circuitry and reference reside in packages that are
separate and distinct from the regulator control circuitry and reference. No
single point fault is able to cause a sustained over voltage condition on any
or all outputs. The power supply provides latch-mode over voltage
protection defined as:
+5V output is between 5.7V to 6.5V
+12V output is between 13.3V to 15.5V
+3.3V output is between 3.7V to 4.5V
3.7.3 Short Circuit Protection
The power supply DC outputs are protected from damage due to faults,
when any output shorts to ground. In the event of a short circuit on any
output, all outputs shall be disabled and remain disable until the power
supply is powered off and back on. The 5VSB rail will recover upon
removal of the over current condition.