Intermec 073294-001 User Manual

Page of 113
Chapter 2 — Replacing Parts 
Turn the scan engine assembly over and remove the two Phillips screws 
that attach the scan engine and ground spring to the small scan mount 
bracket. 
Disconnect the scan flex cable from the scan engine assembly. 
 
 
Screw
(3 places)
Screw
(2 places)
EV10 scan
flex cable
Engine
insulator
Engine 
ground
spring
EV10 scan
engine assembly
Small scan
mount 
bracket
 
Assemble the new scan engine for replacement: 
Remove the backing from the engine insulator and attach it to the 
top of the scan engine assembly. 
Connect the scan flex cable to the scan engine assembly. Make sure 
you completely insert the scan flex cable up to the white alignment 
mark. 
Insert the EV10 scan engine assembly into the ground spring, place it 
inside the scan mount bracket, and attach it with the two screws 
removed in Step 4. 
Insert the scan engine assembly into the bottom cover and attach it with 
the three screws removed in Step 2. 
Close the CK30. For help, see “Closing the CK30” on page 27. 
24 
CK30 Handheld Computer Service Manual