Alcatel-Lucent OS9-GNI-U24 User Manual

Page of 90
 
 
Alcatel-Lucent 
Page 9 
 
OmniSwitch 9000
 
 
 
 
  
 
 
 
 
 
OmniSwitch 9800 Chassis Technical Specifications 
OmniSwitch 9800 
The OmniSwitch 9800 is a 18-slot large enterprise core 
switch. The OmniSwitch 9800 offers up to 384 Gigabit 
Ethernet ports and can also be equipped with up to  
32/96 (Fully-populated with 16 x OS9-XNI-U2 and/or 
OS9-XNI-U6 modules, with each XNI containing two or 
six XFPs) 10-Gigabit Ethernet ports. 
The OmniSwitch 9800 chassis contains the following 
major components: 
• Sixteen Network Interface (NI) module slots 
• Two Chassis Management Module (CMM) slots 
• Power supply bay holding up to four power supplies 
• Fan tray with three fans 
Total slots per chassis 
18 
Total slots for network interface (NI) modules 
16 
Total slots for Chassis Management Module (CMM) 
Total bays for power supplies 
Total 10/100/1000BASE-T copper 10/100/1000Mbps Ethernet ports available 
384 (Fully populated with OS9-GNI-C24).  
No other NI module types installed. 
Total 10/100/1000BASE-T copper 10/100/1000Mbps Ethernet ports with PoE available 
384 (Fully-populated with 16 x OS9-GNI-P24 modules) 
No other NI module types installed. 
Total 1000BASE-X fiber Gigabit Ethernet ports available 
384 (Fully populated with OS9-GNI-U24 modules).  
No other NI module types installed. 
Total 10GBASE-X 10-Gigabit Ethernet ports available 
Wire-rate: 32 (Fully populated with OS9-XNI-U2 
modules, with each XNI containing two XFPs. No other NI 
modules installed.) 
Oversubscribed: 96 (Fully populated with OS9-XNI-U6 
modules, with each XNI containing six XFPs. No other NI 
modules installed.) 
The oversubscription ratio is: 2.5:1 
Power Consumption 
OS9800-Chassis & Fans = 80W 
Full Duplex support 
Full duplex is supported on Gigabit Ethernet ports and  
10-Gigabit Ethernet ports. 
Environmental Requirements 
OmniSwitch 9000 Series switches have the following 
environmental and airflow requirements: 
• The installation site must maintain a temperature between 
0° and 45° Celsius (32° and 113° Fahrenheit) and not 
exceed 95 percent maximum humidity (non-condensing) at 
any time. 
• Be sure to allow adequate room for proper air ventilation 
at the front, back, and sides of the switch. No clearance is 
necessary at the top or bottom of the chassis. 
Electrical Requirements 
OmniSwitch 9000 Series switches have the following 
general electrical requirements: 
• Each switch requires one grounded electrical outlet for 
each power supply installed in the chassis (up to four for 
OS9800 switches, up to three for OS9700 switches; up to 
two for OS9600 switches). 
OmniSwitch 9000 Series switches offer both AC and DC 
power supply support. For switches using AC power 
connections, each supplied AC power cord is 2 meters 
(approximately 6.5 feet) long. Do not use extension cords. 
Redundant AC Power. It is recommended that each AC 
outlet reside on a separate circuit. With redundant AC, if a 
single circuit fails, the switch’s remaining power supplies 
(on separate circuits) are likely to remain unaffected and 
can, therefore, continue operating. 
OmniSwitch 9800 Chassis Dimensions 
Overall Width (including rack-mount flanges) 
19 1/8 inches 
Chassis Width (rack-mount flanges not included) 
17 9/16 inches 
Height 
29 1/4 inches 
Height (rack units) 
17 RU 
Overall Depth (including required fan tray) 
17 5/16 inches 
Chassis Depth (fan tray not included) 
14 3/4 inches