High Power PP-750 Pro HPC-750-B14S User Manual

Product codes
HPC-750-B14S
Page of 14
 
        Switching Power Supply Specifications
 
 
 
Page 
 
 
 
 
3.  Output characteristics 
 
3.1  Normal Operation Output  
Output 
Voltage 
Load     
MIN 
Range 
MAX 
Regulation
Ripple P-P 
Max. 
Ripple & Noise 
P-P Max. 
1. +5V 
0.2A 
22.0A 
±5% 
70mV 100mV 
2. 
+12V 0.6A 54.0A  ±5% 
120mV 200mV 
3. –12V 
0.0A 
0.3A 
±10% 
150mV 200mV 
4. +5Vs 
0.0A 
3.0A 
±5% 
70mV 100mV 
5. +3.3V 
0.1A 
22.0A 
±5% 
70mV 100mV 
 
z  Maximum continuous total DC output power should not exceed 750W. 
z  Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not exceed 130W. 
z  Maximum combined load on 12V outputs shall not exceed 648W. 
NOTE: 
Noise test should be measured with 20 MHz bandwidth frequency oscilloscope. The output terminal 
shall add a tantalum capacitor of 10uF in parallel with a ceramic capacitor of 0.1uF. 
 
 
 
3.2  Remote On/Off Controlled mode 
The PSON# signal is required to remotely turn on/off the power supply, PSON# is an active 
low signal that turns on the output power rails. When this is not pulled low by the system, 
or left open, the outputs (except the +5VSB) turn off. This signal is pulled to a standby 
voltage by a pull-up resistor internal to the power supply.  
 
 
 
TTL  level       "H" 2.0 V - 5.25 V 
"L" 0.0 V – 1.0 V 
 
3.3 Regulation 
The cross regulation defined as follows, the output regulation should be within the specified 
range. 
Load 
+5V +3.3V +12V  -12V +5Vsb 
Light 
Load. 
2.95A 2.95A 10.16A 0.06A 
0.56A 
Typical 
Load 
7.37A 7.37A 25.42A 0.14A  1.41A 
Full Load 
14.75A
14.75A 
50.84A 
0.28 A 
2.82A 
 
 
3.4 Rise 
Time 
DC output rise time is less than 20 mS at nominal line and full load. 
 
 
3.5 Hold-up 
Time 
DC +5V output maintains at least 12mS after power off  which hold within para 3.1  under 
115V/60Hz and 230V/50Hz  condition.