Page
5
3. Output characteristics
3.1 Normal Operation Output
Output
Voltage
Voltage
Load
MIN
Range
MAX
Regulation
Ripple P-P
Max.
Ripple & Noise
P-P Max.
1. +5V
0.2A
22.0A
±5%
70mV 100mV
2.
+12V 0.6A 54.0A ±5%
120mV 200mV
3. –12V
0.0A
0.3A
±10%
150mV 200mV
4. +5Vs
0.0A
3.0A
±5%
70mV 100mV
5. +3.3V
0.1A
22.0A
±5%
70mV 100mV
z Maximum continuous total DC output power should not exceed 750W.
z Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not exceed 130W.
z Maximum combined load on 12V outputs shall not exceed 648W.
NOTE:
Noise test should be measured with 20 MHz bandwidth frequency oscilloscope. The output terminal
shall add a tantalum capacitor of 10uF in parallel with a ceramic capacitor of 0.1uF.
3.2 Remote On/Off Controlled mode
The PSON# signal is required to remotely turn on/off the power supply, PSON# is an active
low signal that turns on the output power rails. When this is not pulled low by the system,
or left open, the outputs (except the +5VSB) turn off. This signal is pulled to a standby
voltage by a pull-up resistor internal to the power supply.
low signal that turns on the output power rails. When this is not pulled low by the system,
or left open, the outputs (except the +5VSB) turn off. This signal is pulled to a standby
voltage by a pull-up resistor internal to the power supply.
TTL level "H" 2.0 V - 5.25 V
"L" 0.0 V – 1.0 V
3.3 Regulation
The cross regulation defined as follows, the output regulation should be within the specified
range.
range.
Load
+5V +3.3V +12V -12V +5Vsb
Light
Load.
2.95A 2.95A 10.16A 0.06A
0.56A
Typical
Load
7.37A 7.37A 25.42A 0.14A 1.41A
Full Load
14.75A
14.75A
50.84A
0.28 A
2.82A
3.4 Rise
Time
DC output rise time is less than 20 mS at nominal line and full load.
3.5 Hold-up
Time
DC +5V output maintains at least 12mS after power off which hold within para 3.1 under
115V/60Hz and 230V/50Hz condition.