Power Sub-system 
Intel
®
 Entry Server Chassis SC5299-E TPS 
  
Revision 
3.1 
Intel order number D37594-005 
28 
Table 24. AC Line Sag Transient Performance 
Duration 
Sag 
Operating AC Voltage 
Line 
Frequency 
Performance Criteria 
Continuous 
10% 
Nominal AC Voltage ranges 
50/60Hz 
No loss of function or performance 
0 to 1 AC cycle 
100% 
Nominal AC Voltage ranges 
50/60Hz 
No loss of function or performance 
> 1 AC cycle 
>10% 
Nominal AC voltage ranges 
50/60Hz 
Loss of function acceptable, self 
recoverable 
Table 25. AC Line Surge Transient Performance 
Duration 
Surge 
Operating AC Voltage 
Line Frequency 
Performance Criteria 
Continuous 
10% 
Nominal AC Voltages 
50/60Hz 
No loss of function or performance 
0 to ½ AC 
cycle 
30% 
Mid-point of nominal AC 
voltages 
50/60Hz 
No loss of function or performance 
 
2.2.2.3 
Susceptibility Requirements 
The power supply meets the following electrical immunity requirements when connected to a 
cage with an external EMI filter that meets the criteria defined in the SSI document EPS Power 
Supply Specification.  
Table 26. Performance Criteria 
Level 
Description 
The apparatus shall continue to operate as intended. No degradation of 
performance. 
The apparatus shall continue to operate as intended. No degradationof 
performance beyond spec limits. 
Temporary loss of function is allowed provided the function is self-recoverable or 
can be restored by the operation of the controls. 
 
2.2.2.3.1 
Electrostatic Discharge Susceptibility 
The power supply complies with the limits defined in EN 55024: 1998 using the IEC 61000-4-
2:1995 and the level 3 test standard and performance criteria B defined in Annex B of CISPR 
24.