 Entry Server Chassis SC5299-E TPS 
Power Sub-system 
Revision 3.1 
 
 
Intel order number D37594-005 
47
2.3.2.2 
Efficiency 
The power supply has a minimum efficiency of 75% at maximum load and over an 90-264VAC 
line voltage range to guarantee proper power supply cooling while mounted in the system. 
2.3.2.3 
AC Input Voltage Specification 
The power supply operates within all specified limits over the following input voltage range, as 
shown in following table. Harmonic distortion of up to 10% of rated AC input voltage will not 
cause the power supply to go out of specified limits. The power supply powers off at or 
after/below 75VAC +/-5VAC range. The power supply starts up at or before/above 85VAC +/-
4VAC. Application of an input voltage below 85VAC does not cause damage to the power 
supply, including a fuse blow. 
Table 52. AC Input Rating 
Parameter 
MIN 
Rated 
MAX 
Start up VAC 
Power Off VAC 
Max Input 
Current 
Max Rated 
Input AC 
Current 
Voltage (110) 
90 V
rms
 100-127 
V
rms
 140 
V
rms
 85Vac 
+/-
4Vac 
75Vac +/-
5Vac 
9.63 A
rms
1,3
 8.7 
A
rms
4
 
Voltage (220) 
180 V
rms
 200-240 
V
rms
 264 
V
rms
 
 
 
4.82 A
rms
2,3
 4.4 
A
rms
4
 
Frequency 
47 
Hz 
50/60Hz 
63 
Hz 
    
Notes: 
Maximum input current at low input voltage range shall be measured at 90Vac, at max load. 
Maximum input current at high input voltage range shall be measured at 180VAC, at max load.  
This is not to be used for determining agency input current markings. 
Maximum rated input current is measured at 100VAC and 200VAC. 
2.3.2.4 
AC Line Transient Specification 
AC line transient conditions are defined as “sag” and “surge” conditions. “Sag” conditions are 
also commonly referred to as “brownout,” these conditions will be defined as the AC line voltage 
dropping below nominal voltage conditions. “Surge” will be defined to refer to conditions when 
the AC line voltage rises above nominal voltage. The power supply meets the requirements 
under the following AC line sag and surge conditions. 
Table 53. AC Line Sag Transient Performance 
Duration 
Sag 
Operating AC 
Voltage 
Line Frequency 
Loading 
Performance Criteria 
Continuous 10% 
Nominal 
AC 
Voltage ranges 
50/60Hz 
100% 
No loss of function or performance 
0 to 1 AC 
cycle 
100% Nominal 
AC 
Voltage ranges 
50/60Hz 
60% 
No loss of function or performance