Panasonic CS-E21PKEW Leaflet

Page of 2
Etherea with enhanced Econavi sensor and new Nanoe-G air-purifying system: outstanding 
efficiency, comfort and healthy air combined with state-of-the-art design.
Econavi features an in-built human activity sensor and a new sunlight detection technology to adjust output 
thereby giving you the best comfort at anytime whilst saving energy. Econavi not only optimizes air flow 
orientation and volume according to human presence, it also reduces cooling power automatically by no/less 
sunshine. With Econavi, energy savings of up to 38% are possible, whilst increasing your comfort.
Furthermore, the Nanoe-G revolutionary air-purifying system utilises nano technology fine particles to remove 
and deactivate 99% of both airborne and adhesive micro-organisms like bacteria, viruses and mould.
WALL MOUNTED ETHEREA
INVERTER+
SILVER PLATED / WHITE
INTERNET CONTROL READY: Optional. SEER and SCOP: For KIT-XE18-PKE and KIT-XE18-PKE. MILD DRY: Maintains a Relative Humidity up to 10% higher than cooling operation. Ideal when sleeping with the air conditioner on.
A
 class
energy saving
Easy
control
by BMS
CONNECTIVITY
5 year
compressor
warranty
Up to 
38%
energy savings
(cooling)
Air purifier 
99%
 
removal
bacteria · virus · mold
Perfect
humidity
control
MILD DRY
Improved
comfort
AUTOCOMFORT
Internet
Control
Ready
INTERNET CONTROL
OPTIONAL
Kit Silver Plated
KIT-XE18-PKE
KIT-XE21-PKE
Kit Silver Plated / with Smartphone Control
KIT-XE18-PKE-WIFI
KIT-XE21-PKE-WIFI
Kit White
KIT-E18-PKE
KIT-E21-PKE
KIT-E24-PKE
KIT-E28-PKE
Kit White / with Smartphone Control
KIT-E18-PKE-WIFI
KIT-E21-PKE-WIFI
KIT-E24-PKE-WIFI
KIT-E28-PKE-WIFI
Indoor Silver plated
CS-XE18PKEW
CS-XE21PKEW
Indoor White
CS-E18PKEW
CS-E21PKEW
CS-E24PKEW
CS-E28PKES
Outdoor
CU-E18PKE
CU-E21PKE
CU-E24PKE
CU-E28PKE
Cooling capacity
Nominal (Min - Max)
kW
5.00 (0.98-6.00)
6.30 (0.98-7.10)
6.80 (0.98-8.10)
7.65 (0.98-8.60)
Nominal (Min - Max)
kCal/h
4,300 (840-5,160)
5,420 (840-6,110)
5,850 (840-6,970)
6,580 (840-7,400)
EER 
1)
Nominal (Min - Max)
Energy Saving 3,47 (3.50-3,02) 
A
2.89 (3.50-2.84) 
C
3.27 (2.58-3.06) 
A
3.04 (2.58-2.95) 
B
SEER
Nominal
Energy Saving 6.9 
A++
6.5 
A++
6.1 
A++
6.0 
A+
Pdesign (cooling)
5.0
6.3
6.8
7.7
Power input Cooling
Nominal (Min - Max)
kW
1.44 (0.28-1.99)
2.18 (0.28-2.50)
2.08 (0.38-2.65)
2.52 (0.38-2.92)
Annual Energy Consumption (Cooling) 
2)
kWh
254
339
390
449
Heating capacity
Nominal (Min - Max)
kW
5.80 (0.98-8.00)
7.20 (0.98-8.50)
8.60 (0.98-9.90)
9.60 (0.98-11.00)
Heating capacity at -7 °C
Nominal
kW
4,990 (840-6,880)
6,190 (840-7,310)
7,400 (840-8,510)
8,260 (840-9,460)
COP 
1)
Nominal (Min - Max)
Energy Saving 3.82 (2.88-3.11) 
A
3.44 (2.88-3.11) 
B
3.31 (2.18-3.16) 
C
2.94 (2.18-2.97) 
D
SCOP
Nominal
Energy Saving 4.2 
A+
4.0 
A+
3.8 
A
3.6 
A
Pdesign at -10 °C
kW
4.4
4.6
5.5
6.0
Power input Heating
Nominal (Min - Max)
kW
1.520 (0.340-2.570)
2.09 (0.34-2.73)
2.60 (0.45-3.13)
3.26 (0.45-3.70)
Annual Energy Consumption (Heating) 
2)
kWh
1467
1610
2026
2333
Indoor Unit
Power source
V
230
230
230
230
Recommended Fuse
A
Recommended power cable section
mm²
Connection indoor / outdoor
mm²
4 x 2.5
4 x 2.5
4 x 2.5
4 x 2.5
Current (Nominal)
Cooling / Heating
A
6.4 / 6.8
9.7 / 9.4
9.5 / 11.8
11.5 / 14.6
Max. current
A
11.3
11.9
13.8
15.5
Air Volume
Cooling / Heating
m³/h
1074 / 1158
1,034 / 1,200
1,188 / 1,272
1,266 / 1,314
Moisture removal volume
l/h
2.8
3.5
3.9
4.5
Sound pressure Level 
2)
Cooling (Hi / Lo / S-Lo) dB(A)
44 / 37 / 34
45 / 37 / 34
47 / 38 / 35
49 / 38 / 35
Heating (Hi / Lo / S-Lo) dB(A)
44 / 37 / 34
45 / 37 / 34
47 / 38 / 35
48 / 38 / 35
Sound power Level
Cooling / Heating (Hi)
dB
60 / 60
61 / 61
63 / 63
65 / 64
Dimensions 
3)
H x W x D
mm
295 x 1,070 x 255
295 x 1,070 x 255
295 x 1,070 x 255
295 x 1,070 x 255
Net weight
kg
13
13
13
13
Air purifier filter
Nanoe-G
Nanoe-G
Nanoe-G
Nanoe-G
Outdoor Unit
Air Volume
Cooling / Heating
m³/h
2,352 / 2,274
2,502 / 2,424
3,012 / 3,012
3,270 / 3,270
Sound pressure Level 
2)
Cooling / Heating (Hi)
dB(A)
47 / 47
48 / 49
52 / 52
53 / 53
Sound power Level
Cooling / Heating (Hi)
dB
61 / 61
62 / 63
66 / 66
67 / 67
Dimensions 
3)
H x W x D
mm
695 x 875 x 320
695 x 875 x 320
795 x 875 x 320
795 x 875 x 320
Net weight
kg
46
47
67
67
Piping connections
Liquid pipe / Gas pipe
inch (mm)
1/4" (6.35) / 1/2" (12.70)
1/4" (6.35) / 1/2" (12.70)
1/4" (6.35) / 5/8" (15.88)
1/4" (6.35) / 5/8" (15.88)
Refrigerant Loading
R410A (GWP value)
kg
1.24
1.32
1.80
1.80
Elevation difference (in/out) 
4)
Max
m
15
15
20
20
Piping length
Min / Max
m
3 / 20
3 / 20
3 / 30
3 / 30
Precharge length
Max
m
7.5
7.5
10
10
Additional charge
g/m
20
20
30
30
Operating range
Cooling Min / Max
°C
-10 / +43
-10 / +43
-10 / +43
-10 / +43
Heating Min / Max
°C
-15 / +24
-15 / +24
-15 / +24
-15 / +24
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Heating Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: JKE units are not compatible with PKE units.
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in 
accordance with Eurovent 6/C/006-97 specification. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.doc.panasonic.de
Awarded with the prestigious
IF Design Award 2013
6.9 A++
SEER
SEASONAL ENERGY 
EFFICIENCY RATIO
4.2 A+
SCOP
SEASONAL COEFFICIENT  
OF PERFORMANCE
38