EFFICIENCY
PRODUCT FOLLOWS THE NEW
ErP ECODESIGN REQUIREMENTS
A
++
SCOP
KIT SILVER PLATED: KIT-XE18-PKE // KIT-XE21-PKE
KIT WHITE: KIT-E18-PKE // KIT-E21-PKE // KIT-E24-PKE //
KIT-E28-PKE
KIT-E28-PKE
Technical focus
· MAXIMUM EFFICIENCY AND COMFORT WITH ECONAVI, NOW WITH SUNLIGHT
DETECTION
· NANOE-G AIR PURIFYING SYSTEM, 99% EFFECTIVE ON BOTH AIRBORNE AND
ADHESIVE MOULD, VIRUSES AND BACTERIA
· OPTIONAL SMARTPHONE CONTROL
· MILD DRY COOLING: PREVENT A RAPID DECREASE IN ROOM HUMIDITY
· MORE POWERFUL AIRFLOW TO QUICKLY REACH THE DESIRED TEMPERATURE
Features
HEALTHY AIR
· Nanoe-G air purifying system
· Mild Dry Cooling operation mode for increased comfort and prevention of skin moisture loss
· Nanoe-G air purifying system
· Mild Dry Cooling operation mode for increased comfort and prevention of skin moisture loss
ENERGY, EFFICIENCY AND ECOLOGY
· Maximum efficiency Inverter system, for bigger savings
· -45% consumption with Econavi on heat pump, and -38% on cooling mode
· R410A refrigerant gas
· Maximum efficiency Inverter system, for bigger savings
· -45% consumption with Econavi on heat pump, and -38% on cooling mode
· R410A refrigerant gas
COMFORT
· Super Quiet mode (from 20 dB)
· Powerful mode
· Uniform dispersion of airflow
· Automatic vertical airflow control
· Hot start mode, increased comfort on heat pump mode, no cool airflow when process starts
· Automatic restart after power cut
· Super Quiet mode (from 20 dB)
· Powerful mode
· Uniform dispersion of airflow
· Automatic vertical airflow control
· Hot start mode, increased comfort on heat pump mode, no cool airflow when process starts
· Automatic restart after power cut
EASE OF USE
· Real time clock with dual ON&OFF timer
· User friendly infrared remote control
· Optional wired weekly timer with 6 settings per day and 42 settings per week
· Connectivity function (indoor unit equipped with PCB port which can be connected to
· Real time clock with dual ON&OFF timer
· User friendly infrared remote control
· Optional wired weekly timer with 6 settings per day and 42 settings per week
· Connectivity function (indoor unit equipped with PCB port which can be connected to
outside network)
· Optional Smartphone control
EASY INSTALLATION AND MAINTENANCE
· Removable, washable panel
· 15 m maximum connection distance
· 15 m maximum elevation difference
· Maintenance access through the top panel of the outdoor unit
· Self-diagnosis function
· Removable, washable panel
· 15 m maximum connection distance
· 15 m maximum elevation difference
· Maintenance access through the top panel of the outdoor unit
· Self-diagnosis function
CU-E18PKE
CU-E21PKE
CU-E21PKE
INCLUDED WITH
THE INDOOR UNIT
THE INDOOR UNIT
OPTIONAL
WIRED REMOTE CONTROL
CZ-RD514C
WIRED REMOTE CONTROL
CZ-RD514C
CU-E24PKE
CU-E28PKE
CU-E28PKE
CS-XE18PKEW // CS-XE21PKEW // CS-XE24PKES // CS-XE28PKES
CS-E18PKEW // CS-E21PKEW //
CS-E24PKES // CS-E28PKES
CS-E24PKES // CS-E28PKES
ROTARY
INVERTER COMPRESSOR
NEW AIR FLOW DISCHARGE IDEAL AIR FLOW FOR HEATING AND FOR COOLING
IDEAL AIR FLOW DISCHARGE
ON COOLING MODE
IDEAL AIR FLOW DISCHARGE
ON HEATING MODE
Airflow in
Cooling Mode
Cooling Mode
Airflow in
Heating Mode
Heating Mode
2 air guides
to improve
the air flow
direction
to improve
the air flow
direction
2 air guides to
improve the air
flow direction
improve the air
flow direction