Self-adjusting LEDs
The LED brightness adjusts automatically to the
surrounding light level. A blue light-emitting diode
(LED) indicates TriTech+ alarms and activates during a
walk test. A yellow LED indicates microwave
detection, and a red LED indicates PIR detection.
Remote Walk Test LED
Users can enter a command through a keypad, a
control center, or programming software to remotely
enable or disable the walk test LED.
Alarm Memory
Alarm memory flashes the alarm LED to indicate
stored alarms for use in multiple unit applications. A
switched voltage from the control panel controls the
alarm memory.
Solid State Relays
Solid state relays send silent alarm output signals to
provide a higher level of security and reliability. An
external magnet does not activate the relay. The solid
state relay uses less current than a mechanical relay,
providing longer standby capacity during a power loss.
Draft, Insect, and Small Animal Immunity
The sealed optic chamber provides immunity to drafts
and insects, reducing false alarms. Small animal
immunity reduces false alarms caused by animals less
than 4.5 kg (10 lb), such as rodents.
Remote Self Test
A remote self test initiates when the walk test input
switches to its true state. The alarm relay and alarm
LED activate for four seconds following a successful
test. The trouble relay activates, and the alarm LED
flashes following a failed test.
Input Power Supervision
When the power is lower than 8 V, a low input power
trouble condition activates the trouble relay and
causes the LED to flash. The trouble condition clears
automatically when power reaches or exceeds 8 V.
Trouble Memory
When the walk test input switches to its true state for
less than two seconds, the LED flashes to indicate the
most recent trouble condition. If there is no trouble in
memory, the LED does not flash. After twelve hours, or
after the detector receives a second walk test pulse
for two seconds or less, the LED stops flashing and
the trouble memory clears.
DIP Switch Programming
The following functions are all programmed using DIP
switch settings:
• Local Walk Test LED
• Remote Walk Test Input Polarity
• Alarm Memory Polarity
• MANTIS Anti-mask On and Off
Certifications and approvals
Europe
EN
50131-5 Environmental Class II
 
 
50102 IK04
 
 
60529 IP41
 
WEEE
Waste Electrical and Electronic
Equipment Directive
The detectors are designed to also comply with requirements of:
USA
FCC
Complies with Part 15
Region
Certification
Australia
RCM
Europe
CE
2004/108/EC EMC Directive (EMC);
2006/95/EC Low-Voltage Directive
(LVD); 1999/5/EC Radio equipment and
Telecommunications Terminal Equip-
ment (R&TTE); 2011/65/EU Restriction
of the use of certain hazardous substan-
ces in electrical and electronic equip-
ment(RoHS) [-WC30G, -WC30H]
EN5013
1
EN 50131-2-4: 2008, Grade 2
Belgium
INCERT
B-509-0052/f [-WC30G]
France
AFNOR
2820200005 [-WC30G]
AFNOR
2820200005 [-WC30H]
Sweden
INTYG
Nr11-780 [-WC30G]
Brazil
ANATEL
1772-11-1855 [-WC30G]
Installation/configuration notes
Coverage Patterns
Standard Curtain Coverage 30 m x 2.6 m (100 ft x
8.6 ft)
Mounting Considerations
The recommended mounting height is 2.1 m to 3 m
(7 ft to 10 ft).
Use an optional B328 Gimbal‑mount Bracket or B335
Low‑profile Swivel‑mount Bracket to surface mount
the detector on a flat wall or in a corner.
Use an optional B338 Universal Ceiling Bracket to
mount the detector on the ceiling.
Wiring Considerations
Recommended wire size is 0.2 mm
2
 to 1 mm
(26 AWG
to 16 AWG).
2 | ISC-PDL1-WC30x Professional Series TriTech Curtain Detectors