Bosch ISC-PDL1-WC30G User Manual

Page of 4
Parts included
Quantity
Component
1
Detector
1
Hardware pack containing 2 flat-head screws, 2 screw
anchors, and a nylon cable tie
1
Literature pack
• Installation Guide
Technical specifications
Electrical
Power Requirements
Voltage (Operating):
9 VDC to 15 VDC
Current (Maximum):
< 26 mA with alarm, trouble, and LEDs
active.
Current (Standby):
18 mA at 12 VDC
Outputs for both Models
Tamper:
Normally-closed (NC) contacts (with cover
on) rated at 25 VDC, 125 mA maximum.
Connect tamper circuit to 24-hour
protection circuit.
Trouble:
Solid state relay normally-closed (NC)
contacts.
Alarm:
Solid state relay, normally-closed (NC)
contacts, power supervised.
3 W, 125 mA, 25 DC, resistance < 10 Ω.
Mechanical
Enclosure Design
Color:
White
Dimensions:
127 mm x 69 mm x 58 mm
(5 in. x 2.75 in. x 2.25 in.)
Material:
High-impact ABS plastic
Indicators
Alarm Indicator:
• Blue LED for TriTech+ alarms
• Yellow LED for microwave detection
• Red LED for PIR detection
Zones
Zones:
28
Environmental
Relative Humidity:
0 to 95%, non-condensing
Temperature (Operating
and Storage):
-30°C to +55°C (-22°F to +130°F)
For AFNOR certificated installations,
-10°C to +55°C (+14°F to +130°F)
For UL Certificated installations, 0°C to
+49°C (+32°F to +120°F)
Environmental Rating
(EN 50130‑5):
Class II
Protection Rating
(EN 60529, EN 50102):
IP41, IK04
Ordering information
ISC‑PDL1‑WC30G Professional Series TriTech Curtain
Detector (30 m, 10.525 GHz)
Provides PIR and microwave, 30 m x 3 m (100 ft x 10
ft) coverage.
Order number 
ISC-PDL1-WC30G
ISC‑PDL1‑WC30H Professional Series TriTech Curtain
Detector (30 m, 10.588 GHz)
Provides PIR and microwave, 30 m x 3 m (100 ft x 10
ft) coverage. For use in France and the United
Kingdom.
Order number 
ISC-PDL1-WC30H
 
3 | ISC-PDL1-WC30x Professional Series TriTech Curtain Detectors