Intel Pentium D 830 HH80551PG0802MN Data Sheet

Product codes
HH80551PG0802MN
Page of 106
 
Datasheet
75
Thermal Specifications and Design Considerations
5
Thermal Specifications and 
Design Considerations
5.1
Processor Thermal Specifications
The Intel
®
 Pentium
®
 D processor requires a thermal solution to maintain temperatures within 
operating limits as set forth in 
. Any attempt to operate the processor outside these 
operating limits may result in permanent damage to the processor and potentially other components 
within the system. As processor technology changes, thermal management becomes increasingly 
crucial when building computer systems. Maintaining the proper thermal environment is key to 
reliable, long-term system operation.
A complete thermal solution includes both component and system level thermal management 
features. Component level thermal solutions can include active or passive heatsinks attached to the 
processor Integrated Heat Spreader (IHS). Typical system level thermal solutions may consist of 
system fans combined with ducting and venting.
For more information on designing a component level thermal solution, refer to the Intel
®
 
Pentium
®
 D Processor and Intel
®
 Pentium
®
 Processor Extreme Edition 840 Thermal and 
Mechanical Design Guidelines.
Note:
The boxed processor will ship with a component thermal solution. Refer to 
the boxed processor.
5.1.1
Thermal Specifications
To allow for the optimal operation and long-term reliability of Intel processor-based systems, the 
system/processor thermal solution should be designed such that the processor remains within the 
minimum and maximum case temperature (T
C
) specifications when operating at or below the 
Thermal Design Power (TDP) value listed per frequency in 
. Thermal solutions not 
designed to provide this level of thermal capability may affect the long-term reliability of the 
processor and system. For more details on thermal solution design, refer to the appropriate 
processor thermal design guidelines.
The Pentium D processor has a methodology for managing processor temperatures that is intended 
to support acoustic noise reduction through fan speed control. Selection of the appropriate fan 
speed will be based on the temperature reported by the processor’s Thermal Diode. If the diode 
temperature is greater than or equal to T
CONTROL
, then the processor case temperature must remain 
at or below the temperature as specified by the thermal profile. If the diode temperature is less than 
T
CONTROL
, then the case temperature is permitted to exceed the thermal profile, but the diode 
temperature must remain at or below T
CONTROL
. Systems that implement fan speed control must 
be designed to take these conditions into account. Systems that do not alter the fan speed only need 
to ensure the case temperature meets the thermal profile specifications.
To determine a processor's case temperature specification based on the thermal profile, it is 
necessary to accurately measure processor power dissipation. Intel has developed a methodology 
for accurate power measurement that correlates to Intel test temperature and voltage conditions.