Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
CAPACITIES AND SELECTION DATA
 
 
4-9 
 
 
4.2. 
CAPACITY CHARACTERISTIC CURVES FOR MONOZONE/MULTIZONE 
 
The  following  charts  show  the  characteristics  of  outdoor  unit  capacity,  which  corresponds  with  the  operating  ambient 
temperature of outdoor unit. 
Conditions: 
Pipe length / height difference : 7.5m / 0m 
Compressor at rated inverter frequency 
Indoor fan speed at High mode 
Capacity loss due to white frost and defrost operation is not included. 
 
4.2.1.  RAI-25RPA/RAC-25NPA 
COOLING [50Hz, 230V] 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INDOOR 
OUTDOOR TEMPERATURE (°CDB) 
EWB  EDB 
-10 
21 
27 
32 
35 
40 
43 
°C 
°C  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI 
12.0  18  2649   1991  528  2200   1947  460  2036   1797  542  2050  1820  639  1975  1740  667  1850  1640  716  1775  1560  744 
14.0  20  2649   1991  528  2364   1947  460  2200   1816  548  2200  1820  646  2125  1760  674  1975  1640  723  1900  1580  758 
16.0  22  2649   2119  536  2528   1947  466  2340   1816  555  2350  1820  653  2275  1760  688  2125  1640  737  2050  1580  765 
18.0  25  2840   2272  545  2691   2116  472  2481   1966  561  2500  1980  660  2400  1900  688  2250  1780  744  2150  1700  771 
19.0  27  2936   2349  553  2785   2228  478  2574   2060  567  2600  2080  667  2500  2000  695  2350  1880  744  2250  1800  771 
22.0  30  3255   2323  553  3089   2209  478  2855   2041  567  2875  2060  674  2775  1980  702  2500  1920  771  2325  1880  813 
24.0  32  3479   2323  561  3300   2209  484  3043   2041  574  3075  2060  674  2950  1980  709  2600  1960  792  2375  1940  841 
 
 
HEATING [50Hz, 230V] 
INDOOR 
OUTDOOR TEMPERATURE (°CDB) 
  
EDB 
-15 
-10 
-7 
-5 
10 
15 
  
°C 
TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI 
  
16 
1260 
0  696 1995 
0  714 2275 
0  745 2461 
0  765 2996 
0  856 3539 
0  868 3861 
0  891 4456 
0  935 
  
18 
1243 
0  705 1978 
0  724 2253 
0  761 2436 
0  785 2965 
0  878 3521 
0  912 3847 
0  931 4438 
0  979 
  
20 
1225 
0  714 1960 
0  733 2233 
0  773 2415 
0  799 2940 
0  893 3500 
0  940 3763 
0  973 4410 
0 1025 
  
22 
1208 
0  724 1943 
0  743 2205 
0  789 2380 
0  820 2909 
0  915 3479 
0  978 3805 
0 1009 4389 
0 1067 
  
24 
1190 
0  733 1925 
0  752 2185 
0  804 2359 
0  839 2884 
0  936 3458 
0 1015 3784 
0 1047 4326 
0 1110 
 
 
 
EWB : Evaporator Wet Bulb temperature (
C) 
 
TC : Total Capacity (W) 
EDB : Evaporator Dry Bulb temperature (
C) 
 
SHC : Sensible Heating Capacity (W) 
(
CDB) : Outdoor Unit Inlet Air Dry Temperature (
C) 
 
PI : Power Input