CAPACITIES AND SELECTION DATA
 
 
4-11 
 
 
HEATING [50Hz, 230V] 
INDOOR 
OUTDOOR TEMPERATURE (°CDB) 
  
EDB 
-15 
-10 
-7 
-5 
10 
15 
  
°C 
TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI 
  
16 
2340 
0 1598 3705 
0 1642 4224 
0 1712 4570 
0 1758 5564 
0 1968 6572 
0 1994 7170 
0 2048 8275 
0 2149 
  
18 
2308 
0 1620 3673 
0 1663 4184 
0 1748 4524 
0 1804 5506 
0 2017 6539 
0 2095 7144 
0 2138 8242 
0 2251 
  
20 
2275 
0 1642 3640 
0 1685 4147 
0 1776 4485 
0 1836 5460 
0 2052 6500 
0 2160 6988 
0 2236 8190 
0 2354 
  
22 
2243 
0 1663 3608 
0 1706 4095 
0 1813 4420 
0 1884 5402 
0 2102 6461 
0 2246 7066 
0 2318 8151 
0 2452 
  
24 
2210 
0 1685 3575 
0 1728 4059 
0 1849 4381 
0 1929 5356 
0 2151 6422 
0 2333 7027 
0 2406 8034 
0 2551 
 
 
4.2.4.  RAD-25RPA/RAC-25NPA 
COOLING [50Hz, 230V] 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INDOOR 
OUTDOOR TEMPERATURE (°CDB) 
EWB  EDB 
-10 
21 
27 
32 
35 
40 
43 
°C  °C  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI 
12.0  18  2541  1910  507  2110  1868  441  1953  1724  520  2050  1820  639  1975  1740  667  1850  1640  716  1775  1560 744 
14.0  20  2541  1910  507  2267  1868  441  2110  1742  526  2200  1820  646  2125  1760  674  1975  1640  723  1900  1580 758 
16.0  22  2541  2033  514  2424  1868  447  2245  1742  532  2350  1820  653  2275  1760  688  2125  1640  737  2050  1580 765 
18.0  25  2724  2180  522  2582  2029  453  2380  1886  538  2500  1980  660  2400  1900  688  2250  1780  744  2150  1700 771 
19.0  27  2816  2253  530  2671  2137  459  2469  1976  544  2600  2080  667  2500  2000  695  2350  1880  744  2250  1800 771 
22.0  30  3122  2229  530  2963  2119  459  2739  1958  544  2875  2060  674  2775  1980  702  2500  1920  771  2325  1880 813 
24.0  32  3337  2229  538  3165  2119  464  2918  1958  550  3075  2060  674  2950  1980  709  2600  1960  792  2375  1940 841 
 
HEATING [50Hz, 230V] 
INDOOR 
OUTDOOR TEMPERATURE (°CDB) 
  
EDB 
-15 
-10 
-7 
-5 
10 
15 
  
°C 
TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI  TC  SHC  PI 
  
16 
1260 
0  718 1995 
0  737 2275 
0  769 2461 
0  790 2996 
0  884 3539 
0  895 3861 
0  920 4456 
0  965 
  
18 
1243 
0  728 1978 
0  747 2253 
0  785 2436 
0  810 2965 
0  906 3521 
0  941 3847 
0  960 4438 
0 1011 
  
20 
1225 
0  737 1960 
0  757 2233 
0  798 2415 
0  825 2940 
0  922 3500 
0  970 3763 
0 1004 4410 
0 1057 
  
22 
1208 
0  747 1943 
0  766 2205 
0  814 2380 
0  846 2909 
0  944 3479 
0 1009 3805 
0 1041 4389 
0 1101 
  
24 
1190 
0  757 1925 
0  776 2185 
0  830 2359 
0  866 2884 
0  966 3458 
0 1048 3784 
0 1081 4326 
0 1146 
 
 
 
EWB : Evaporator Wet Bulb temperature (
C) 
 
TC : Total Capacity (W) 
EDB : Evaporator Dry Bulb temperature (
C) 
 
SHC : Sensible Heating Capacity (W) 
(
CDB) : Outdoor Unit Inlet Air Dry Temperature (
C) 
 
PI : Power Input