Hitachi RAF-35RPA RAF35RPA User Manual
Product codes
RAF35RPA
CAPACITIES AND SELECTION DATA
4-287
4.3.28. RAK-35PSPA/RAC-35WSPA
COOLING [50Hz, 230V]
INDOOR
OUTDOOR TEMPERATURE (°CDB)
EWB EDB
-10
21
27
32
35
40
43
°C °C TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
12.0 18
2954 2131 511 3011 2558 547 2787 2361 644 2870 2445 777 2765 2338 811 2590 2203 870 2485 2095 904
14.0 20
2954 2131 511 3235 2558 547 3011 2386 652 3080 2445 786 2975 2365 820 2765 2203 879 2660 2123 921
16.0 22
2954 2268 519 3460 2558 554 3203 2386 659 3290 2445 794 3185 2365 837 2975 2203 896 2870 2123 930
18.0 25
3168 2432 527 3684 2779 561 3396 2582 667 3500 2660 803 3360 2553 837 3150 2391 904 3010 2284 938
19.0 27
3275 2514 535 3812 2927 568 3524 2705 675 3640 2794 811 3500 2687 845 3290 2525 904 3150 2418 938
22.0 30
3631 2487 535 4228 2902 568 3908 2681 675 4025 2768 820 3885 2660 853 3500 2579 938 3255 2525 989
24.0 32
3880 2487 543 4517 2902 575 4164 2681 682 4305 2768 820 4130 2660 862 3640 2633 963 3325 2606 1022
HEATING [50Hz, 230V]
INDOOR
OUTDOOR TEMPERATURE (°CDB)
EDB
-15
-10
-7
-5
0
7
10
15
°C
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
16
1440
0 614 2280
0 631 2599
0 658 2812
0 676 3424
0 756 4044
0 766 4412
0 787 5092
0 826
18
1420
0 623 2260
0 639 2574
0 671 2784
0 693 3388
0 775 4024
0 805 4396
0 822 5072
0 865
20
1400
0 631 2240
0 647 2552
0 682 2760
0 706 3360
0 789 4000
0 830 4300
0 859 5040
0 905
22
1380
0 639 2220
0 656 2520
0 697 2720
0 724 3324
0 808 3976
0 863 4348
0 891 5016
0 942
24
1360
0 647 2200
0 664 2498
0 710 2696
0 741 3296
0 827 3952
0 896 4324
0 925 4944
0 980
4.3.29. RAF-25PXA/RAC-25FXA
COOLING [50Hz, 230V]
INDOOR
OUTDOOR TEMPERATURE (°CDB)
EWB EDB
-10
21
27
32
35
40
43
°C °C TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
TC SHC PI
12.0 18
2594 2403 432 2350 2564 410 2175 2366 483 2050 2243 534 1975 2145 557 1850 2021 597 1775 1922 621
14.0 20
2594 2403 432 2525 2564 410 2350 2391 489 2200 2243 539 2125 2169 563 1975 2021 603 1900 1947 632
16.0 22
2594 2557 438 2700 2564 415 2500 2391 495 2350 2243 545 2275 2169 574 2125 2021 615 2050 1947 638
18.0 25
2781 2742 445 2875 2785 421 2650 2588 500 2500 2440 551 2400 2342 574 2250 2194 621 2150 2095 644
19.0 27
2875 2835 452 2975 2933 426 2750 2712 506 2600 2564 557 2500 2465 580 2350 2317 621 2250 2218 644
22.0 30
3188 2804 452 3300 2909 426 3050 2687 506 2875 2539 563 2775 2440 586 2500 2366 644 2325 2317 679
24.0 32
3406 2804 458 3525 2909 432 3250 2687 512 3075 2539 563 2950 2440 592 2600 2415 661 2375 2391 702
HEATING [50Hz, 230V]
INDOOR
OUTDOOR TEMPERATURE (°CDB)
EDB
-15
-10
-7
-5
0
7
10
15
°C
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
16
1224
0 585 1938
0 600 2209
0 626 2390
0 643 2910
0 720 3437
0 729 3750
0 749 4328
0 786
18
1207
0 593 1921
0 608 2188
0 639 2366
0 660 2880
0 738 3420
0 766 3737
0 782 4311
0 823
20
1190
0 600 1904
0 616 2169
0 649 2346
0 672 2856
0 751 3400
0 790 3655
0 818 4284
0 861
22
1173
0 608 1887
0 624 2142
0 663 2312
0 689 2825
0 769 3380
0 822 3696
0 848 4264
0 897
24
1156
0 616 1870
0 632 2123
0 676 2292
0 705 2802
0 787 3359
0 853 3675
0 880 4202
0 933
EWB : Evaporator Wet Bulb temperature (
C)
TC : Total Capacity (W)
EDB : Evaporator Dry Bulb temperature (
C)
SHC : Sensible Heating Capacity (W)
(
CDB) : Outdoor Unit Inlet Air Dry Temperature (
C)
PI : Power Input