Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
 
10-15 
 
• 
In case of make 
a hole on the 
wall 
• 
 
Unit mm 
• 
Sideways piping 
 
 
 WARNING  
• 
For sideways piping, do not install the drain hose 
sideways. Connect the drain hose so that it comes 
out directly. 
• 
Sideways installation of the drain hose will prevent it 
from sloping downward, causing water leakage. To 
avoid dripping, make sure to pass the drain hose 
under the pipe. 
• 
Remove the PIPE SUPPORT. 
• 
Insert the drain hose into the hole in the wall. 
• 
Winding insulation pipe for drain hose and taping 4 
or 5 places to fix. 
• 
Connect the pipe to the indoor unit 
• 
After completing the piping connection, cover the 
connector with a insulator 
 
 
• 
Since there is some space between PIPE 
SUPPORT and the pipe, affix the insulator ⑩ to the 
PIPE SUPPORT. As shown in the figure below, affix 
the insulator ⑩ to the PIPE SUPPORT to sandwich 
it. 
 
• 
After connecting the pipes and connecting cord, be 
sure to screw PIPE SUPPORT, tightly and fix the 
pipes and connecting cord. 
• 
Position the each-to-attach side of PIPE SUPPORT 
(after aligning it with the pipe) to face the front and 
secure it with a screw. (Be sure to install PIPE 
SUPPORT to prevent rodents  from entering the 
indoor unit). 
 
 CAUTION 
• 
When mounting the flare insulator ① , make sure 
there is a space between the insulator and left of 
resin part. Otherwise, may cause water dripping. 
• 
To prevent the pipe connector from contacting the 
front cover, push the connector as far as it goes. 
• 
Arrange the connecting cord, pipes and drain hose 
neatly and store them in the bottom section of the 
rear surface of the indoor unit 
 
Pipe layout of the 
unit rear surface 
 
Pipe/drain hose 
layout when 
passing through 
the file in a wall. 
 
 
Before piping 
Above 270 
30 
After piping 
Small pipe 
Large pipe 
120 
15
80
mm o
r l
es
30
 
R60 
W
al
W
al
Top view 
Wall 
Front view 
Floor 
Right side view 
10
14
80
mm o
r l
es
15
30
 
W
al
R80 
R60 
R60 
Pipe 
Wrap flare 
insulation, bind top 
and bottom flare 
insulation by binder. 
Wrap tape on flare 
insulation closely
Flare 
insulator
 
Binder 
Binder 
PIPE SUPPORT 
Connecting cord 
Pipe 
Insulator 
Insulator 
Pipe 
Insulator 
Drain hose 
Connecting cord 
Indoor unit rear surface