Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
 
10-31 
 
 CAUTION  
• 
Be sure to install the indoor unit level. If the 
indoor unit is inclined, water may leak. 
• 
If the space between bottom surfaces of indoor 
unit and ceiling is not correct, there may be a 
gap between the grille and ceiling surface, which 
will cause dripping of condensed water. 
6.  Change of suction opening and filter position from 
bottom to back side 
• 
Remove the filter at the bottom side of indoor unit 
by unscrew 8 screws at the filter holders (4 
portions). 
• 
Remove 6 screws at back plate of indoor unit. 
• 
Then install the back plate at the bottom of indoor 
unit using 6 screws. 
• 
Install filter at backside of indoor unit by fixing it 
with filter holders (4 portions) using 8 screws. 
 
 
Setting of switches 
High static-pressure switch (Full duct type and semi 
duct type) 
For full duct type and semi duct type, set the high static –
pressure switch to HIGH STATIC-PRESSURE 
If it is not set to HIGH STATIC-PRESSURE, there will be 
reduction of cooling and heating capacities. (At the time of 
delivery, the switch is set as “NORMAL”) 
 
4.  Installation of wired remote controller 
a.  Connection to the electrical box 
• 
Remove the cover of electric box 
• 
Connect the connector of wired remote 
controller to CN1102 
• 
Assemble back the cover of electrical 
box 
b.  Wiring installation for wired remote controller (2 
methods) 
• 
Wired remote controller casing can be 
opened by pressing the slots with minus 
screw driver (see below diagram) 
 
Indoor unit 
Filter 
Filter holders 
Back plate 
(1) Bottom side suction opening 
Indoor unit 
Filter 
Filter holders 
Back plate 
(2) Back side suction opening 
Static-Pressure SW 
ST
AT
IC 
 
PR
ESSU
RE
 
 
This is used for increasing fan speed 
according to the situation of the trial 
operation inside the room with ceiling 
height 2.5m and above.  
However noise gets slightly higher. 
HIGH PRESSURE 
NORMAL 
Wired 
Remote 
Controller