freja outlets
Product information
The Freja series has been designed to meet the visual requirements to a 
modern installation. The Freja can be used with a bricking case or a surface 
mounting frame. In combination with the surface mounting frame a very 
stylish, discrete and universal installation is archived. The series comes in 
TV/FM and multimedia versions and is characterised by having a low insertion 
loss, and a high isolation between outputs.
The outlets all meet the demands of CENELEC Class A screening efficiency. This is especially necessary in 
order to supply an optimal CATV signal, when the outlet is connected to a data modem.
All outlets are assigned colour codes on the IEC constructions, in order to identify the type of outlet on 
the front (See page 23 for more information regarding these codes). For a complete overview of the  
various models please see page 23.
Explanation to “version”: Std = Standard (no diplex), Dip = Diplex filter, TM = Terminated,  
 
LT = Loop-through
Type
Freja T0B-H
Freja T4C-H
Freja T10dB-H
Freja T13dB-H
Freja T16dB-H
Item no.
52260
52263
52266
52269
52272
Version
Std, TM
Std, LT
Std, LT
Std, LT
Std, LT
TV
Frequency range (MHz)
5-68 / 118-1000
5-68 / 118-1000
5-68 / 118-1000
5-68 / 118-1000
5-68 / 118-1000
Insertion loss IN-TV (dB)
0,8
4,0
10,0
13,0
16,0
Return loss EN50083-4*
Cat. C
Cat. C
Cat. C
Cat. C
Cat. C
Connector
IEC-Male
IEC-Male
IEC-Male
IEC-Male
IEC-Male
FM
Frequency range (MHz)
87,5-108
87,5-108
87,5-108
87,5-108
87,5-108
Insertion loss IN-FM (dB)
1,0
4,5
10,0
13,0
16,0
Connector
IEC-Female
IEC-Female
IEC-Female
IEC-Female
IEC-Female
IN & OUT
Frequency range (MHz)
5-862
5-1000
5-1000
5-1000
5-1000
Insertion loss IN-OUT (dB)
-
3,8
1,8
0,9
0,9
Return loss EN50083-4*
Cat. B
Cat. B
Cat. B
Cat. B
Cat. B
Type
Freja MM4-65D-H
Freja MM10-65D-H
Freja MM13-65-H Freja MM16-65-H
Freja ZT301A-H
Item no.
52275
52281
52292
52294
52393
Version
Dip, TM
Dip, LT
Std, LT*
1
Std, LT*
2
Std, TM
DATA
SAT
Frequency range (MHz)
5-1000
5-1000
5-1000
5-1000
950-2150
Insertion loss reverse (dB)
0,8
0,8
12
14
SAT
Insertion loss forward (dB)
4,5
10
12
14
2,5
Return loss EN50083-4*
Cat. B
Cat. B
Cat. B
Cat. B
Cat. B
Isolation to OUT (dB)
-
-
> 25
> 25
-
Isolation to TV
 
(dB) 
5-65 MHz
> 50
> 50
> 55
> 60
-
Isolation to TV (dB) 
118-1000 MHz
> 22
> 22
> 25
> 25
-
Connector
F-Female
F-Female
F-Female
F-Female
F-Female
TV
Frequency range (MHz)
118-1000
118-1000
118-1000
118-1000
47-68 / 118-1000
Insertion loss IN-TV (dB)
4,5
2,0
13
16
2,0
Return loss EN50083-4*
Cat. C
Cat. C
Cat. C
Cat. C
Cat. C
Isolation to OUT (dB)
-
-
> 25
> 25
-
Connector
IEC-Male
IEC-Male
IEC-Male
IEC-Male
IEC-Male
FM
Frequency range (MHz)
87,5-108
87,5-108
87,5-108
87,5-108
87,5-108
Insertion loss IN-FM (dB)
4,5
2,5
14
17
2,0
Connector
IEC-Female
IEC-Female
IEC-Female
IEC-Female
IEC-Female
Dimension (H 77 x W 50 x D 27 mm)
Screening Class A = VHF 85dB, UHF 75dB
IN & OUT 
Frequency range (MHz) 
*
1
 5-1000 
*
5-1000
 
Insertion loss IN-OUT (dB) 
*
1
 2,0 
*
1,7
 
Return loss EN50083-4* 
*
1
 Cat. B 
*
Cat. B
According to CENELEC: 
 
A: 5-40 MHz ≥ 22 dB, min. 14 dB @ 40-1750 MHz ÷ 1,5/oct. 
B: 5-40 MHz ≥ 18 dB, min. 10 dB @ 40-1750 MHz ÷ 1,5/oct. 
C: 5-40 MHz ≥ 14 dB, min. 10 dB @ 40-1750 MHz ÷ 1,5/oct. 
D: 5-1750 MHz ≥ 10 dB