13
odin outlets
Product information
The Odin series has been designed to meet the visual requirements to a 
modern compact installation for the Danish market. The series comes both as 
a TV/FM and as a multimedia outlet and is characterised having low insertion 
loss, and high isolation between the outputs. 
The Odin outlets all meet the demands for the CENELEC Class A screening  
efficiency. This is especially necessary in order to supply an optimal CATV 
signal, when the outlet  is connected to a data modem. A modem emits up to 
120 dBµV and the CENELEC demand to screening efficiency is therefore min.  
81 dBµV.  
 
A high screening efficiency is also necessary to elude the many airborne signals 
in the TV frequency area. This is also a demand the Odin outlets live up to. 
All outlets are assigned colour codes on the IEC constructions, in order to 
identify the type of outlet on the front (See page 23 for more information  
regarding these codes). For a complete overview of the various models please 
see page 23.
Explanation to “version”: Std = Standard (no diplex), Dip = Diplex filter,  
TM = Terminated, LT = Loop-through
Type *
Odin T0B-H
Odin T4C-H
Odin T13dB-H
Odin MM4-65D-H
Odin MM10-65D-H
Item no.
52230
52235
52240
52244
52247
Version
Std, TM 
Std, LT
Std, LT
Dip, TM
Dip, TM
DATA
Frequency range (MHz)
-
-
-
5-1000
5-1000
Insertion loss reverse (dB)
-
-
-
0,8
0,8
Insertion loss forward (dB)
-
-
-
4,5
10
Return loss EN50083-4*
-
-
-
Cat. B
Cat. B
Isolation to TV
 
(dB) 
5-65 MHz
-
-
-
> 50
> 50
Isolation to TV (dB) 
118-1000 MHz
-
-
-
> 22
> 22
Connector
-
-
-
F-Female
F-Female
TV
Frequency range (MHz)
5-68 / 118-1000
5-68 / 118-1000
5-68 / 118-1000
118-1000
118-1000
Insertion loss IN-TV (dB)
0,8
4,0
13
4,5
2,5
Return loss EN50083-4*
Cat. C
Cat. C
Cat. C
Cat. C
Cat. C
Connector
IEC-Male
IEC-Male
IEC-Male
IEC-Male
IEC-Male
FM
Frequency range (MHz)
87,5-108
87,5-108
87,5-108
87,5-108
87,5-108
Insertion loss IN-FM (dB)
1,0
4,5
13
4,5
2,5
Connector
IEC-Female
IEC-Female
IEC-Female
IEC-Female
IEC-Female
IN & OUT
Frequency range (MHz)
5-1000
5-1000
5-1000
5-1000
5-1000
Insertion loss IN-OUT (dB)
-
3,8
0,9
-
-
Return loss EN50083-4*
Cat. B
Cat. B
Cat. B
Cat. B
Cat. B
Dimension (H 66 x W 66 x D 36 mm)
Screening Class A = VHF 85dB, UHF 75dB
*According to CENELEC: 
 
 
A: 5-40 MHz ≥ 22 dB, min. 14 dB @ 40-1750 MHz ÷ 1,5/oct. 
 
B: 5-40 MHz ≥ 18 dB, min. 10 dB @ 40-1750 MHz ÷ 1,5/oct. 
 
C: 5-40 MHz ≥ 14 dB, min. 10 dB @ 40-1750 MHz ÷ 1,5/oct. 
 
D: 5-1750 MHz ≥ 10 dB