Ideal Networks Serie 33-960 Cable tester, cable tester 33-960-3 User Manual

Product codes
33-960-3
Page of 123
Description of Event Types
104
IDEAL
Reflective Event (Possible Echo)
Reflective Event (Possible Echo)
This symbol indicates a reflective event that can be a real reflection or an 
echo produced by another stronger reflection located closer to the source.
³
In the example above, the launched pulse hits the third connector, is 
reflected back to the OTDR and reflected again into the fiber. It then 
reaches the third connector a second time and is reflected once more 
to the OTDR.
The application would therefore detect a reflective event located at 
twice the distance of the third connector. Since this event is almost null 
(no loss), and since its distance is a multiple of the third connector 
distance, The application would interpret it as a possible echo.
³
A reflectance value is specified for reflective events (possible echo).
Reflected power 
(dB)
Distance
(km)
OTDR connector
Second connector
Third connector
Reflective event (possible echo)