Voltcraft DSO-1062D 2-Channel Oscilloscope, Digital Storage Oscilloscope DSO-1062D User Manual

Product codes
DSO-1062D
Page of 84
Specifications 
DSO-1062D Digital Oscilloscope User Manual                                             62 
Chapter 8 Specifications 
8.1  Technical Specifications 
All specifications  herein mentioned apply to the DSO-1062D  oscilloscopes.  Before checking  an 
oscilloscope from our company to see if it complies with these specifications, make sure it meets 
the following conditions: 
  The oscilloscope must have been operating continuously for  twenty minutes under  the 
specified operating temperature. 
  The Do  Self Cal operation  must be performed  through  the Utility menu if the operating 
temperature changes by more than 5℃. 
  The oscilloscope must be within the factory calibration interval. 
All specifications are guaranteed unless noted ‘typical’. 
Oscilloscope Specifications 
Horizontal 
Sample Rate Range 
500MS/s dual channel 
Waveform Interpolation 
(sin x)/x 
Record Length 
Maximum 1M  samples per single-channel;  maximum 512K  
samples per dual-channel (4K, 40K optional) 
SEC/DIV Range 
4ns/div to 40s/div, in a    2, 4, 8 sequence 
Sample Rate and 
Delay Time Accuracy 
±50ppm over any ≥1ms time interval 
Delta Time Measurement 
Accuracy   
(Full Bandwidth) 
Single-shot, Normal mode 
± (1 sample interval +100ppm × reading + 0.6ns) 
>16 averages   
± (1 sample interval + 100ppm × reading + 0.4ns) 
Sample interval = s/div ÷ 200 
Position Range 
20ns/div to 
80μs/div 
(-8div × s/div) to 40ms 
200μs/div to 40s/div 
(-8div × s/div) to 400s 
Vertical 
A/D Converter 
8-bit resolution, 
each channel sampled simultaneously 
VOLTS/DIV Range 
2mV/div to 5V/div at input BNC 
Position Range 
2mV/div to 200mV/div, ±2V 
>200mV/div to 5V/div, ±50V