Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S User Manual

Product codes
MSO1074Z-S
Page of 172
RIGOL 
DS1000Z Programming Guide 
2-55
 
:MEASure:ADISplay   
Syntax 
:MEASure:ADISplay <bool> 
:MEASure:ADISplay? 
Description 
Enable or disable all measurement function, or query the status of all measurement 
function.   
Parameter 
Name 
Type 
Range 
Default 
<bool> 
Bool 
{{0|OFF}|{1|ON}} 
0|OFF 
 
Explanation 
  The all measurement function can measures the following 20 parameters of the 
source at the same time:   
Voltage Parameters: Vmax, Vmin, Vpp, Vtop, Vbase, Vamp, Vavg, Vrms, Overshoot 
and Peshoot 
Time Parameters: Period, Frequency, Rise Time, Fall Time, + Width, - Width, + Duty 
and - Duty 
Other Parameters: Area and Period Area.   
  The all measurement function can measures the parameters of CH1, CH2, CH3 and 
CH4 at the same time. You can sent th
 command to set the 
source of the all measurement function.   
Return 
Format
 
The query returns 0 or 1.   
Example 
:MEASure:ADISplay ON 
Related 
Command 
 
 
:MEASure:AMSource 
Syntax 
:MEASure:AMSource <src>[,<src>[,<src>[,<src>]]] 
:MEASure:AMSource? 
Description 
Set or query the source of the all measurement function. 
Parameter 
Name 
Type 
Range 
Default 
<src> 
Discrete 
{CHANnel1|CHANnel2|CHANnel3|CHANnel4} 
CHANnel1 
 
Return 
Format 
The query returns CHAN1, CHAN2, CHAN3 or CHAN4.   
Example 
:MEASure:AMSource CHANnel1,CHANnel3