DS1000Z User’s Guide
 
 
9-3  
 
Test and Ouput 
 
Before the test, you can use the following method to set the output mode of the test 
results.   
Press Stat.Disp to select “ON” or “OFF”. When “ON” is selected, the test results will 
be displayed at the upper right corner of the screen.   
 
 
Press Stat.Disp to clear the current statistic and restatistic the test result. 
 
Press Stop On Fail to select “ON” or “OFF”.   
  ON: when failed waveforms are detected, the oscilloscope will stop the test and 
enter the “STOP” state. At this point, the results of the test remain the same on 
the screen (if display is turned on) and only one pulse is output from the 
[Trigger Out] connector (if enabled) at the rear panel. 
  OFF: the oscilloscope will continue with the test even though failed waveforms 
are detected. The test results on the screen will update continuously and a pulse 
will be output from the [Trigger Out] connector at the rear panel each time a 
failed waveform is detected.   
 
Press Output to select “
” or “ ”. 
 
: failed waveforms are detected, there are display and output but the beeper 
does not sound. 
 
: failed waveforms are detected, there are display and output and the beeper 
sounds (not related to the on/off state of the sound). 
 
Press AuxOutput to quickly turn “ON” or “OFF” the output of test results from the 
[Trigger Out] connector at the rear panel. You can also press Utility  
AuxOutput and select “PassFail” to set this output.