--press Data Bits to select “5 bits”, “6 bits”, “7 bits” or “8 bits”;   
--press Data and input the data value according to the setting in Data Bits and 
the upper limits are 31, 63, 127 and 255 respectively. 
 
Baud Rate: 
Set the baud rate of data transmmision (equal to specifying a clock frequency). Press 
Baud to set the desired baud rate to 2400 (default), 4800, 9600, 19200, 38400, 
57600, 115200 and user-defined, the default unit is bps. When “User” is selected, 
press Setup and use 
  to set a more specific value from 1 to 900000 with an 
adjustment step of 1 bps. 
 
Trigger Mode: 
Press Sweep to select the 
 (page 
) under this trigger type as auto, 
normal or single. The corresponding status light of the current trigger mode turns on. 
 
Trigger Setting: 
Press Setting to set the trigger parameter (noise rejection) under this trigger type. 
 
Trigger Level: 
Use TRIGGER    LEVEL to modify the level. For details, please refer to the 
description of 
 on page 
.