Specifications 
Need intro paragraph here 
General Specifications 
Maximum Voltage Applied to any Terminal ........ 600 V ac rms or dc 
Storage Temperature .......................................... -40 
°
C to 60 
°
C (-40 
°
F to 140 
°
F) 
Operating Temperature....................................... -20 
°
C to 55 
°
C (-4 
°
F to 131 
°
F) 
Temperature Coefficient...................................... 0.05 x (specified accuracy) per 
°
C for temperatures < 18 
°
C or > 28 
°
 (< 64 
°
F or > 82 
°
F) 
Relative Humidity ................................................ Noncondensing  
0 % to 95 % @ 10 
°
C to 30 
°
C (50 
°
F to 86 
°
F) 
0 % to 75 % @ 30 
°
C to 40 
°
C (86 
°
F to 104 
°
F) 
0 % to 40 % @ 40 
°
C to 55 
°
C (104 
°
F to 131 
°
F) 
Vibration .............................................................. Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument 
Shock .................................................................. 1 meter drop per IEC 61010-1 2
nd
 Edition (1 meter drop test, six sides, oak floor) 
Electromagnetic Compatibility............................. In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997). 
Safety .................................................................. Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and 
IEC/EN 61010-1 2
nd
 Edition for measurement category IV 600 V (CAT IV)  
Certifications ....................................................... CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 
2
nd
 Edition 
Batteries .............................................................. Four AA batteries (NEDA 15A or IEC LR6) 
Battery Life .......................................................... Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline 
batteries at room temperature. These are standard tests of 1000 V into 1 M
Ω
 with a duty 
cycle of 5 seconds on and 25 seconds off. Resistance Measurements: Tester can perform 
at least 2500 earth-bond resistance measurements with fresh alkaline batteries at room 
temperature. These are standard tests of 1 
Ω
 with a duty cycle of 5 seconds on and 25 
seconds off. 
Size ..................................................................... 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) 
Weight ................................................................. 550 g (1.2 lb.)