2. dELIvErY CONtENt
Lamp tester LT-100
4 Micro batteries (AAA, LR03, 24A)
Operating instructions
3. INtENdEd uSE
The lamp tester serves as a diagnosis and error search device on gas filled lighted systems.
It can check gas filled lighting up to a maximum of 100 watts in voltage free status for functionality. 
Possible light types: High and low pressure sodium discharge lamps, neon tubes, fluorescent tubes , mercury vapor 
lamps, energy saving lamps (not suitable for LED or incandescent lamps).
The gas filled light is ionized via a high frequency voltage via a telescopic antenna on the test device and should 
light up during correct function. The test ca be carried out in an installed or dismantled state. The user should not 
touch the light with the hands. The antenna should not be touched during the test.
An additional test tests the heating coil of the fluorescent tubes. An optical and acoustic continuity test should be 
carried out on both plug contacts of the T series lamps.
An integrated LED torch also enables work in badly lit environments.
The lamp tester is certified for the area of measuring category CAT III to a maximum 300 V to earth potential in 
accordance with EN 61010-1, as well as all lower measuring categories. The test device may not be used in the 
vicinity of measuring category CAT IV. No extreme voltage may be applied at the telescope test antenna.
The test device is operated via four commercial 1.5 V micro batteries (Type AAA, LR03). The multimeter may be 
operated with the specified battery type only. Batteries with a cell voltage of 1.2 V may not be used. An automatic 
power-off function prevents premature battery drain.
The device may not be operated when opened, with open battery compartment or missing battery compartment 
cover. 
Testing in explosive areas (Ex) or humidors or under unfavorable ambient conditions is not permitted. Adverse 
ambient conditions are defined as such: Dampness or a high level of humidity, dust and flammable gases, vapors 
or solvents as well as thunderstorms or thunderstorm conditions such as strong electrostatic fields etc. Likewise 
changing batteries in this area is prohibited. 
The device may only be operated by persons who are familiar with the required regulations for testing and possible 
dangers. The use of personal protective equipment is recommended.
Any use other than that described above will damage the product and may involve other hazards such as short-
circuit, fire, electric shock, etc. The product as a whole must not be modified or altered! 
Read this user manual completely before first use and keep it for future reference.