Voltcraft LT-100Tester LT-100 Data Sheet
Product codes
LT-100
VOLTCRAFT® - TOP PERFORMANCE IN EVERY WAY
“For more than 25 years, our product range has been dynamically adapting to the constant changes in the industry. We
commit to offering first-class quality to our customers while delivering an excellent cost-performance ratio. This philosophy
remains the cornerstone of Voltcraft’s success.”
LT-100
LAMP TEsTER
VERsION 08/14
Nº 1214311
Handy lamp tester for current gas filled low and high pres-
sure lamps. Testing ceiling lamps in the socket without a
ladder is also possible using the telescopic antenna.
In addition a continuity tester enables the testing of the
In addition a continuity tester enables the testing of the
heating coil. An LED torch is integrated for badly lit areas.
FEATUREs:
For neon, energy saving, fluorescent, mercury vapor and
sodium discharge lamps // continuity tester for filament
test // integrated LED torch // telescopic antenna 68 cm //
EqUIPMENT:
Single handed operation possible // extremely compact
// integrated telescopic antenna extendable up to 68 cm
// compatible with all fluorescent (electro luminescence)
lamps up to 100 W: T2, T4, T5, T8, T9, T10, T12, energy
saving fluorescent lamps, sodium discharge-low pres-
sure lamps, sodium discharge-high pressure lamps, neon
tubes, mercury vapor lamps // integrated LED torches //
optical/acoustic display.
PACkAgE CONTENTs:
Batteries // Instruction Manual.
Legal notice
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing.
© Copyright 2014 by Conrad Electronic sE
These operating instructions represent the technical status at the time of printing.
© Copyright 2014 by Conrad Electronic sE
V1_0814_02/VTP
G
TEChNICAL dATA:
Test interval "TEST"
approx. 1 second
Test voltage
max. 3000 V/AC, 68 kHz - 72 kHz
Telescopic antenna length
approx. 68 cm
Heating coil test
T2, T4, T5, T8, T9, T10, T12
Automatic power-off
5 minutes
Power supply
4 Micro batteries (AAA)
Power input
approximately 400 mA (Impulse)
Operating conditions
0 to 40°C (<75%rF non condensing)
Storage conditions
-10 to +50°C (<75%rF non condensing)
Operating altitude
max. 2000 m
Battery change alarm
<4,5 V, acoustic
Alarm signal
>70 dB
Weight
approx. 226 g
Dimensions (LxWxH)
220 x 55 x 30 (mm)
Measuring category
CAT III 300 V
Contamination level
2