4.3.2 
Correlation of Measurement and Model Data Inductance 
To correlate the measurement and model data for loop inductance, one unit of measured socket 
assembly (socket and shorted test fixture) and one unit of measured sandwich (shorted test fixture) 
will be chosen for cross sectioning. Both units will be modeled based on data from cross sectioning 
using Ansoft* 3D. The sandwich inductance will be subtracted from socket assembly inductance for 
both measured and modeled data. This procedure results in loop inductance for socket contact. This 
final result can be compared with the loop inductance from the supplier model for the socket. If 
there is any difference between them, it will be called the de-embedded correction factor. Adding 
the test board to the socket and then eliminating the contribution of the fixture creates this correction 
factor because inductance is not linear. 
4.4 Pin-to-Pin 
Capacitance 
Pin-to-pin capacitance shall be measured using configuration 4, with the motherboard not connected 
and only the measurements with the package mounted on the socket will be taken. Capture data at 
frequency specified in item 5 of
. 
4.5 
Dielectric Withstand Voltage 
No disruptive discharge or leakage greater than 0.5 mA is allowed when subjected to 360 V RMS. 
The sockets shall be tested according to EIA-364, Test Procedure 20A, Method 1. The sockets shall 
be tested unmounted and unmated. Barometric pressure shall be equivalent to Sea Level. The 
sample size is 25 contact-to-contact pairs on each of 4 sockets. The contacts shall be randomly 
chosen. 
4.6 Insulation 
Resistance 
The Insulation Resistance shall be greater than 800 M Ohm when subjected to 500 V DC. The 
sockets shall be tested according to EIA-364, Test Procedure 21. The sockets shall be tested 
unmated and unmounted. The sample size is 25 contact-to-contact pairs on each of 4 sockets. The 
contacts shall be randomly chosen. 
4.7 
Contact Current Rating 
Measure and record the temperature rise when the socket is subjected to rated current of 0.8A. The 
sockets shall be tested according to EIA-364, Test Procedure 70A, Test Method 1. The sockets shall 
be mounted on a test-board and mated with a package so those 370 pins are connected in series. The 
recommended Test-board is the FSETV4 Rev 1 and the recommended package is FSETV5 Rev 1. 
The wiring list is shown below. Mount the thermocouple as near to contact N3 or N 7 as possible. 
Short the daisy chains by means of the edge fingers if possible. Sample size is one socket.