Brennenstuhl 1172660 Data Sheet

Page of 36
Power Jet-Light 4 x 36 W  IP54 
Instruction manual 
16
 Status:
 
7201S-04-2008_K
 
6.2 Change 
lamp 
 DANGER:
  
Disconnect mains plug before opening the working lamp! 
Let working lamp cool down before touching it (at least 15 minutes).  
Any contact might cause burns. 
 
Step 
Operation 
Turn working light on the “back“. Press rubber lip down.  
Pos. Description 
7 Protective 
cover 
8 Rubber 
lip 
13 Casing 
 
Figure 3: Remove rubber lip 
Table 4: Remove rubber lip 
 
Unscrew the 4 screws of the protective cover  from casing. Remove protective 
cover. 
Pos. Description 
13 Casing 
15  Protective cover screws 
 
Figure 4: Open protective cover 
 
Table 5: Open protective cover 
 
 
Remove lamp from socket by pulling it upwards. 
Pos.  Description 
6 Socket 
 
9 Lamp 
 
Figure 5: Socket 
 
Table 6: Socket
 
 
Insert new lamp with light pressure.  
Put protective cover on the casing. Screw the 4 screws of the protective cover into 
the protective cover. Put sealing over protective cover again. 
 IMPORTANT: See that the sealing sits correctly between casing and 
protective cover.