8.0 
SENSOR REHYDRATION 
NOTICE 
SENSOR REHYDRATION 
 
Exposure to elevated temperatures, such as those 
experienced during solder reflow, may dry out the sensing 
element. It is recommended that the sensor be allowed 
time to rehydrate after soldering or other high 
temperature/dry exposures. 
 
Exposure to these conditions will not permanently 
damage the sensor. It will generally return to its factory-
calibrated value after rehydration. 
 
If rehydration is not performed, the sensor may read a 
slight offset that slowly disappears over time as the 
sensor becomes exposed to ambient conditions. 
Conversely, extended exposure to condensing and high 
humidity environments (>90 %RH) may cause a revisable 
shift in readings which will generally return to normal after 
the sensor has been allowed to dry off.
 
 
To rehydrate the sensor, expose it to room temperature under 
ambient conditions (>50 %RH) for a minimum of five hours. 
 
9.0 
DIMENSIONS 
 
Figure 2: Landing pattern. 
 
Figure 3: Tape and reel. 
Figure 2. Landing Pattern (For reference only. mm/[in].)
 
 
8X 0,61
     [0.024]
8X 2,03
     [0.08]
4X 4,9
     [0.193]
6X 1,27
     [0.05]
 
 
 
 
 
 
 
 
Figure 3. Tape and Reel Dimensions (For reference only. mm/[in])