Jeti 11-channel receiver 2.4 GHz FHSS with Connector system JR 80001225 User Manual

Product codes
80001225
Page of 26
computer radio control system
EN
6.2 Measure
Measure:  enables  read  out  of  measured  data  of  the  maximum, 
minimum and actual receiver voltage.
Volt Min / Act / Max-   the receiver is checking the supply voltage 
and indicates limit values and extremes which
occurred during operation; at the same time it also shows the actual 
receiver voltage. Without switching on the paired
transmitter the values MAX and MIN will not change, only the value 
of the actual voltage ACT will be updated. In order
to delete values MAX and MIN, keys L (arrow left) and R (arrow right) 
must be pressed simultaneously.
6.3 Main Setting
Fail Safe - switches the Fail Safe function on and off.  If the Fail Safe 
function  is  disabled,  there  are  no  signals  generated  on  receiver 
outputs in case of signal loss. If the Fail Safe function is activated, 
the receiver outputs are generated according your your  individual 
channel setup selections in case of signal loss. („out off“, „hold“,“ fail 
safe“)
Signal  Fault  Delay  -    the  time  interval,  from  when  the  receiver 
detects signal loss to when the fail safe control throws are initiated.  
After the expiration of this time, the receiver outputs will transition 
to your selected individual channel outputs.
Volt ACT/ALARM: the first item displays the actual receiver supply