Best location for installation
·   At first you need install one unit in the bedroom and route way, if you have 
several bedrooms, you’d better install each alarm in every room.
·   Install it in the stairway and in every floor.
·   Smoke, heat and burning things will spread horizontally after rising to the 
ceiling, so install the alarm on middle of the ceiling of ordinary structure house,
let the alarm induce every corner.
·   If alarm couldn’t be installed in the middle of the ceiling for some reasons, the
distance which the alarm away form the wall corner should be beyond 10cm.
·   If installed the alarm on the wall, it should be 10cm below the ceiling (see the
diagram 1).
·   If the length of the room or the hall is beyond 30 foot, you need install several
alarms in the hall.
·   When the wall or ceiling is slanting, the alarm needs to be installed 4 foot away
from the highest wall or ceiling point in the room (see the diagram 2). 
Installation
·   Turn the alarm body counterclockwise and take off the bracket.
·   According to the ”Wireless base description” Section to operate the smoke
alarm. Ensure the radio-link function is ok. Then press the wireless base on 
the installation position, mark installation hole of wireless base with pencil.
·   Bore two installation hole on the sign with electric drill. Make diameter of 
holes is 5mm, Strike the two plastic plugs into holes with hammer.
·   Attach the wireless base to the plastic plugs and fix tightly the screws
(3*20mm) into the plastic plugs. ( refer to Diagram 3). 
·   Fix the 2 batteries into the battery box.
·   Attach the bracket to the wireless base and fix tightly the screws (3*14mm)
into the wireless base. 
·   Connect the signal connector to signal plug.
·   Fit the alarm on the bracket and turn the alarm body clockwise, until matching
well on the bracket.
·   Test smoke alarm using test button. The alarm will sound 3 short beeps – 
1.5 seconds pause, then repeat it until release the button.
·   During testing, may the other smoke detector will alarm. Once release the but-
ton, others will stop alarming in 1 minute. In such a way, you can check the
radio-link function.
WARNING:
To prevent injury, this unit must be securely attached to the wall or ceiling in 
accordance with the installation instructions.
Disposal instructions
Electronic devices and used up batteries are not be thrown into the domestic
waste. Hand in the used batteries at the corresponding collecting point. Hand 
in the device at your municipal waste disposal company or a collecting point 
specialized in electronic scrap.
Disclaimer
Cordes-Vertriebsgesellschaft mbH shall not be liable for damage of any kind (in-
cluding individual or consequential damage) resulting from the fact that the signal
of the smoke alarm was not activated in the presence of smoke.
Furthermore, Cordes-Vertriebsgesellschaft mbH shall also not be held liable for
the consequences of false or deceptive alarmas:  Costs resulting, for instance,
from operations of the fire brigades or key services are not covered.
Cordes-Vertriebsgesellschaft mbH, Op de Solt 42, 22391 Hamburg
Maintenance and Cleaning
In addition to weekly testing, the alarm requires yearly battery replacement and
periodic cleaning to remove dust, dirt, and debris.
You’d better use good battery to let the alarm work longer, some batteries can
use more than 1 year. Please refer to “REPLACE BATTERY”. 
Clean the alarm at least once a month to remove dust, dirt, or debris. Remove 
the battery before cleaning.
Use a vacuum cleaner with the soft brush, vacuum all sides and covers of smoke
alarm. Be sure all the vents are free of debris.
If necessary, Remove the battery and use a damp cloth to clean the alarm’s
cover.
IMPORTANT: Do not attempt to remove the cover to clean inside. This will affect
warranty.
Repair
Caution: Do not attempt to repair the alarm. It will affect your warranty.
If the alarm is not operating properly, and is still under warranty, return it to the
original place you buy. Pack it in a well-padded carton, and ship to the original
place you buy. 
If the alarm is no longer under warranty, have a licensed electrician replace it 
immediately with a comparable alarm.
Practice Fire Safety
If the alarm sounds, and you have not pushed the test button, it is warning of a
dangerous situation, your immediate response is necessary. To prepare for such
occurrences, develop family escape plans, discuss them with all household
members, and practice them regularly.
1  Expose everyone to the sound of a smoke alarm and explain what the sound
means.
2. Determine two exits from each room and an escape route to the outside from
each exit.
3. Teach all household members to touch the door and use an alternate exit
when the door is hot, instruct them not to open the door if the door is hot. 
4. Teach household members to crawl along the floor to stay below dangerous
smoke, fumes and gases.
5. Determine a safe meeting place for all members outside the building.
What to Do in Case of Fire
1. Do not be panic; stay calm.
2. Leave the building as quickly as possible. Touch doors to feel if they were hot
before opening them. Use an alternate exit if necessary. Crawl along the floor,
and do stop to collect anything.
3. Meet at a pre-arranged meeting place outside the building.
4. Call the fire department form outside the building.
5. Do not go back inside a burning building. Wait for the fire department to arrive.
Note: These guidelines will assist you in the event of a fire, however, to reduce
the chance that fires will start, practice fire safety rules and prevent hazardous si-
tuations.
Trouble shooting
DO NOT disconnect battery to quiet an unwanted alarm. This will remove your
protection. Fan the air or open a window to remove smoke or dust.
Problem
Smoke alarm does not sound when 
tested. NOTE: Push the test button 
for at least five seconds while testing! 
Smoke alarm beeps about once 
30 seconds.
Smoke alarm sounds unwanted 
alarms intermittently or when 
residents are cooking, taking 
showers, etc.
The alarm sounds different from 
it is used to. It starts and stops.
Warranty Information
2-year limited smoke alarm warranty Company warrants to the original consumer.
Purchase each new smoke alarm to be free from defects in material and work-
manship under normal use and service for a period of 2 years from the date of
purchase. This warranty does not cover damage resulting from accident, misuse
or abuse or lack of reasonable care of the product.
In no case shall company be liable for any incidental or consequential damages
for breach of this or any other warranty express or implied, whatsoever. The 
bad product can be mailed to the following address with a detail explanation of 
problem.
Before you install the alarm, please read the instruction carefully.
Method of disposal
1. Remove smoke alarm from bracket. 
Then Check the battery is properly 
connect to battery connector.
2. Clean smoke alarm.
Replace battery, please refer to 
“REPLACE BATTERY” section.
1. Clean smoke alarm. Please refer to 
the “maintenance and cleaning” 
section.
2. Hire an electrician to move smoke 
alarm to a new location. 
1. This alarm is operating correctly.
2. Clean smoke alarm. Please refer to the 
“maintenance and cleaning” section.
Halterung
Holes of ceiling or wall
screws 3x20mm
bracket
plugs
Wireless base
diagram 1
diagram 2
screws 3x14mm
Alarm body
diagram 3
GS503W_manual_4xA4_RZ_D/E  28.02.13  15:17  Seite 4