REGISTER 22-3:
BAUDCONx: BAUD RATE CONTROL REGISTER
R/W-0
R-1
R/W-0
R/W-0
R/W-0
U-0
R/W-0
R/W-0
ABDOVF
RCIDL
RXDTP
TXCKP
BRG16
WUE
ABDEN
bit 7
bit 0
Legend:
R = Readable bit
W = Writable bit
U = Unimplemented bit, read as ‘0’
-n = Value at POR
‘1’ = Bit is set
‘0’ = Bit is cleared
x = Bit is unknown
bit 7
ABDOVF:
 Auto-Baud Acquisition Rollover Status bit
1
 = A BRG rollover has occurred during Auto-Baud Rate Detect mode (must be cleared in software)
0
 = No BRG rollover has occurred
bit 6
RCIDL:
 Receive Operation Idle Status bit
1
 = Receive operation is Idle
0
 = Receive operation is active
bit 5
RXDTP:
 Data/Receive Polarity Select bit
Asynchronous mode:
1
 = Receive data (RXx) is inverted (active-low)
0
 = Receive data (RXx) is not inverted (active-high)
Synchronous mode:
1
 = Data (DTx) is inverted (active-low)
0
 = Data (DTx) is not inverted (active-high)
bit 4
TXCKP:
 Synchronous Clock Polarity Select bit
Asynchronous mode:
1
 = Idle state for transmit (TXx) is a low level
0
 = Idle state for transmit (TXx) is a high level
Synchronous mode:
1
 = Idle state for clock (CKx) is a high level
0
 = Idle state for clock (CKx) is a low level
bit 3
BRG16: 
16-Bit Baud Rate Register Enable bit
1
 = 16-bit Baud Rate Generator – SPBRGHx and SPBRGx
0
 = 8-bit Baud Rate Generator – SPBRGx only (Compatible mode), SPBRGHx value ignored
bit 2
Unimplemented: 
Read as ‘0’
bit 1
WUE: 
Wake-up Enable bit
Asynchronous mode:
1
 = EUSART will continue to sample the RXx pin – interrupt generated on falling edge; bit cleared in
hardware on following rising edge
0
 = RXx pin not monitored or rising edge detected
Synchronous mode:
Unused in this mode.
bit 0
ABDEN:
 Auto-Baud Detect Enable bit
Asynchronous mode:
1
 = Enable baud rate measurement on the next character. Requires reception of a Sync field (55h);
cleared in hardware upon completion.
0
 = Baud rate measurement is disabled or has completed
Synchronous mode: