Microchip Technology MCU PIC PIC18F87K22-I/PTRSL TQFP-80 MCP PIC18F87K22-I/PTRSL Data Sheet

Product codes
PIC18F87K22-I/PTRSL
Page of 550
 2009-2011 Microchip Technology Inc.
DS39960D-page 335
PIC18F87K22 FAMILY
22.1.3
AUTO-BAUD RATE DETECT
The Enhanced USART module supports the automatic
detection and calibration of baud rate. This feature is
active only in Asynchronous mode and while the WUE
bit is clear.
The automatic baud rate measurement sequence
(
) begins whenever a Start bit is received
and the ABDEN bit is set. The calculation is
self-averaging.
In the Auto-Baud Rate Detect (ABD) mode, the clock to
the BRG is reversed. Rather than the BRG clocking the
incoming RXx signal, the RXx signal is timing the BRG.
In ABD mode, the internal Baud Rate Generator is
used as a counter to time the bit period of the incoming
serial byte stream.
Once the ABDEN bit is set, the state machine will clear
the BRG and look for a Start bit. The Auto-Baud Rate
Detect must receive a byte with the value, 55h (ASCII
“U”, which is also the LIN/J2602 bus Sync character), in
order to calculate the proper bit rate. The measurement
is taken over both a low and a high bit time in order to
minimize any effects caused by asymmetry of the incom-
ing signal. After a Start bit, the SPBRGx begins counting
up, using the preselected clock source on the first rising
edge of RXx. After eight bits on the RXx pin or the fifth
rising edge, an accumulated value totalling the proper
BRG period is left in the SPBRGHx:SPBRGx register
pair. Once the 5th edge is seen (this should correspond
to the Stop bit), the ABDEN bit is automatically cleared.
If a rollover of the BRG occurs (an overflow from FFFFh
to 0000h), the event is trapped by the ABDOVF status
bit (BAUDCONx<7>). It is set in hardware by BRG roll-
overs and can be set or cleared by the user in software.
ABD mode remains active after rollover events and the
ABDEN bit remains set (
While calibrating the baud rate period, the BRG regis-
ters are clocked at 1/8th the preconfigured clock rate.
The BRG clock will be configured by the BRG16 and
BRGH bits. The BRG16 bit must be set to use both
SPBRG1 and SPBRGH1 as a 16-bit counter. This
allows the user to verify that no carry occurred for 8-bit
modes by checking for 00h in the SPBRGHx register.
Refer to 
 for counter clock rates to the BRG.
While the ABD sequence takes place, the EUSART
state machine is held in Idle. The RCxIF interrupt is set
once the fifth rising edge on RXx is detected. The value
in the RCREGx needs to be read to clear the RCxIF
interrupt. The contents of RCREGx should be
discarded.  
TABLE 22-4:
BRG COUNTER 
CLOCK RATES
22.1.3.1
ABD and EUSART Transmission
Since the BRG clock is reversed during ABD acquisi-
tion, the EUSART transmitter cannot be used during
ABD. This means that whenever the ABDEN bit is set,
TXREGx cannot be written to. Users should also
ensure that ABDEN does not become set during a
transmit sequence. Failing to do this may result in
unpredictable EUSART operation.
Note 1:
If the WUE bit is set with the ABDEN bit,
Auto-Baud Rate Detection will occur on
the byte following the Break character.
2:
It is up to the user to determine that the
incoming character baud rate is within the
range of the selected BRG clock source.
Some combinations of oscillator fre-
quency and EUSART baud rates are not
possible due to bit error rates. Overall
system timing and communication baud
rates must be taken into consideration
when using the Auto-Baud Rate Detection
feature.
3:
To  maximize  baud  rate  range,  if  that
feature is used, it is recommended that
the BRG16 bit (BAUDCONx<3>) be set.
BRG16
BRGH
BRG Counter Clock
0
0
F
OSC
/512
0
1
F
OSC
/128
1
0
F
OSC
/128
1
1
F
OSC
/32