Microchip Technology Microstick for the 5V PIC24F K-series DM240013-2 DM240013-2 Data Sheet

Product codes
DM240013-2
Page of 338
PIC24FV16KM204 FAMILY
DS30003030B-page 280
 
 2013 Microchip Technology Inc.
FIGURE 27-6:
EXTERNAL CLOCK TIMING
OSCI
CLKO
Q4
Q1
Q2
Q3
Q4
Q1
OS20
OS25
OS30
OS30
OS40
OS41
OS31
OS31
Q1
Q2
Q3
Q4
Q2
Q3
TABLE 27-20: EXTERNAL CLOCK TIMING REQUIREMENTS 
AC CHARACTERISTICS
Standard Operating Conditions: 1.8V to 3.6V (PIC24F16KM204)
2.0V to 5.5V (PIC24FV16KM204)
Operating temperature
-40°C 
 T
A
 
 +85°C for Industrial
-40°C 
 T
A
 
 +125°C for Extended
Param
No.
Sym
Characteristic
Min
Typ
(
)
Max
Units
Conditions
OS10 F
OSC
External CLKI Frequency
(External Clocks allowed 
only in EC mode)
DC
4
DC
4



32
8
24
6
MHz
MHz
MHz
MHz
EC, -40°C < T
A
 < +85°C
ECPLL, -40°C < T
A
 < +85°C
EC, -40°C < T
A
 < +125°C
ECPLL, -40°C < T
A
 < +125°C
Oscillator Frequency
0.2
4
4
4
31




4
25
8
6
33
MHz
MHz
MHz
MHz
kHz
XT
HS
XTPLL, -40°C < T
A
 < +85°C
XTPLL, -40°C < T
A
 < +125°C
SOSC
OS20 T
OSC
T
OSC
 = 1/F
OSC
See Parameter 
 for F
OSC
 
value
OS25 T
CY
Instruction Cycle Time
(
62.5
DC
ns
OS30 TosL,
TosH
External Clock in (OSCI)
High or Low Time
0.45 x T
OSC
ns
EC
OS31 TosR,
TosF
External Clock in (OSCI)
Rise or Fall Time
20
ns
EC
OS40 TckR CLKO Rise Time
(
)
 
6
10
ns
OS41 TckF
CLKO Fall Time
6
10
ns
Note 1:
Data in “Typ” column is at 3.3V, +25°C unless otherwise stated. Parameters are for design guidance only 
and are not tested.
2:
Instruction cycle period (T
CY
) equals two times the input oscillator time base period. All specified values are 
based on characterization data for that particular oscillator type, under standard operating conditions, with 
the device executing code. Exceeding these specified limits may result in an unstable oscillator operation 
and/or higher than expected current consumption. All devices are tested to operate at “Min.” values with an 
External Clock applied to the OSCI/CLKI pin. When an External Clock input is used, the “Max.” cycle time 
limit is “DC” (no clock) for all devices.
3:
Measurements are taken in EC mode. The CLKO signal is measured on the OSCO pin. CLKO is low for the 
Q1-Q2 period (1/2 T
CY
) and high for the Q3-Q4 period (1/2 T
CY
).