Microchip Technology MCP9800DM-DL2 User Manual

Page of 22
Installation and Operation
©
 2007 Microchip Technology Inc.
DS22027A-page 9
FIGURE 1-2:
PICkit™ 2 Programmer GUI Window on the PC
7.
Select Device Family>Baseline
8.
Select PIC10F202 from the Device pull-down menu. 
9.
Select File>Import Hex from the File pull-down menu. A file window will appear. 
Locate, select, and open 
SEEVALDM-DL.hex
 from your PC.
10. Click on the Write Device Button in the PICkit™ 2 Programmer window. The 
PIC10F202 will be written to with the 
SEEVALDM-DL.hex
 firmware. Once com-
pleted, the status bar in the middle of the window will indicate Write Successful.
11. Disconnect the MCP9800 Temperature Data Logger Demo Board 2 from the 
PICkit™ 2 programmer. Remove and replace the Power Header (JP1). Led 
should begin flashing indicating that the PIC10F202 is reading temperature from 
the MCP9800 and storing the data into the 24LC16B.
12. LED will flash indicating that measurements are being taken until the 24LC16B 
has reached its storage limit (2,048 bytes).
2.3.2
Reading Data from the MCP9800 Temperature Data Logger 
Demo Board 2 board
1.
Download and install the SEEVAL
® 
32 evaluation tool software using the 
SEEVAL
® 
32 Quick Start User’s Guide.
2.
When the SEEVAL
 
32 evaluation tool software is started the main window will be 
displayed on the PC, as indicated in Figure 1-3.
3.
Select “I2C” from the Protocol pull-down menu.
4.
Select “24AA16/24LC16B” from the Device Name pull-down menu.