TABLE 31-46: ADC CONVERSION (12-BIT MODE) TIMING REQUIREMENTS 
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature
-40°C 
≤  T
A
 
≤  +85°C for Industrial 
-40°C 
≤  T
A
 
≤  +125°C for Extended
Param 
No.
Symbol
Characteristic
Min
Typ
Max
Units
Conditions
Clock Parameters
AD50
T
AD
ADC Clock Period
117.6
ns
AD51
t
RC
ADC Internal RC Oscillator 
Period
250
ns
Conversion Rate
AD55
t
CONV
Conversion Time
14 T
AD
ns
AD56
F
CNV
Throughput Rate
500
Ksps
AD57
T
SAMP
Sample Time
3 T
AD
Timing Parameters
AD60
t
PCS
Conversion Start from Sample 
Trigger
(2)
2 T
AD
3  T
AD
Auto convert trigger not 
selected
AD61
t
PSS
Sample Start from Setting
 
Sample (SAMP) bit
(2)
2 T
AD
3  T
AD
AD62
t
CSS
Conversion Completion to
 
Sample Start (ASAM = 1)
(2)
0.5 T
AD
AD63
t
DPU
Time to Stabilize Analog Stage
 
from ADC Off to ADC On
(2)
20
μs
Note 1: Because the sample caps will eventually lose charge, clock rates below 10 kHz may affect linearity 
performance, especially at elevated temperatures.
2: These parameters are characterized but not tested in manufacturing.
3: The t
DPU
 is the time required for the ADC module to stabilize at the appropriate level when the module is 